Emerson FISHER GX Instruction Manual page 58

Control valve and actuator system
Hide thumbs Also See for FISHER GX:
Table of Contents

Advertisement

GX
COVER PLATE
CAP SCREW
(4)
DOWNSTOP
ACTUATOR
ROD
STEM
CONNECTOR
APPLY
LITHIUM
GREASE TO
LEVERS
DOWNSTOP
3. Screw the adjustable cap screws until the lever
makes light contact with the stem connector.
4. Tighten the back nut on both of the cap screws to
lock the screws in place.
5. Check the actual position of the stem by stroking
the valve with the appropriate air signal to the
actuator.
The standard accuracy for the travel stop position is
"10% for 20mm of travel. For added precision,
fine-tuning can be accomplished as follows:
2
ADJUSTABLE
CAP SCREW (2)
LEVER
STUD AND
NUT (4)
Figure 1. Design GX Travel Stop Assembly
BRACKET
LEVER
BACK NUT (2)
ADJUSTABLE
CAP SCREW (2)
RETAINING RING
SHAFT
Figure 2. Design GX Travel Stop Orientation
COVER PLATE
CAP SCREW
(4)
UPSTOP
APPLY
LITHIUM
GREASE TO
LEVERS
STEM
CONNECTOR
UPSTOP
1. Follow steps 1 through 5, as listed above.
Measure the difference between the actual stem
position and the desired position.
2. Loosen the back nuts and adjust the cap screws
so the valve stem can move.
3. Adjust the air signal to the actuator and stroke the
stem to the desired position.
4. Reset the travel stop by adjusting the cap screws
and moving the lever into contact with the stem
connector. Tighten the back nut on both cap screws.
Errata Sheet
September 2006
LEVER
ADJUSTABLE
STUD AND
CAP SCREW (2)
NUT (4)
ACTUATOR
ROD
LEVER
SHAFT
RETAINING RING
ADJUSTABLE
CAP SCREW
(2)
BACK NUT (2)
BRACKET

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fisher gxFisher design gx

Table of Contents