Technical data common to all models
6.3

Electromagnetic compatibility (EMC)

Radiated disturbance test
Electrostatic discharge immunity
test
Radiated, radio frequency,
electromagnetic field immunity
test
Burst immunity test
Surge immunity test
Immunity to conducted
disturbances inducted by radio
frequency field
Power frequency magnetic field
immunity test
6.4

Durability information

Backlight service life (LED type)
*
Extended use in environments where the surrounding air temperature is 40°C or higher may degrade backlight
quality, reliability or durability.
6.5

Viewing angles

The viewing angles for the horizontal (L, R) and vertical (U, D) axes are specified in reference to the
vertical axis of the display. The viewing angles always refer to the standard mounting orientation.
For the viewing angle values (U, D ,R ,L), refer to the technical data of the respective touch terminal
model.
U: From top D: From bottom
L: From left R: From right
Class A (HMs707, HMs710, HMs715,
HMs721)
Class B (HMs705)
8kV (air electrostatic discharge)
4kV (contact electrostatic discharge)
80MHz–1GHz, 10V/m
1.4–2GHz, 3V/m
2–2.7GHz, 1V/m
±2KV DC power port
±1KV signal line
±0.5KV DC power port (line to earth)
±0.5KV DC power port (line to line)
±1KV signal line (line to earth)
0.15–80MHz, 10V
Enclosure, 50/60Hz, 30A/m
40000 hours or more
(Time of continuous operation until the brightness of the back-
light reaches 50% of the rated value when the surrounding air
temperature is 25°C, see note*)
9
CISPR 22
CISPR 16-2-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8

Advertisement