Installation - IDEC HS5B Manual

Door handle actuator, sliding actuator
Table of Contents

Advertisement

Installation

When using with HS5B-∗∗Z interlock switch
HS5B
36.2
Interlock Switch
Fasten the actuator cover on at least two
oblong holes using mounting screws.
Instructions
Operating Instructions
When using the sliding actuator in a safety-related part of the
system, make sure of proper operation while observing the
safety standards and regulations of the relevant country or re-
gion where the actual machine/system is used. Also, perform
a risk assessment before operation.
Read the instruction sheet of the interlock switch carefully be-
fore installation or operation.
The actuator has projections on the end. Take care not to in-
jure hands.
Regardless of door types, do not use the sliding actuator as a
door stop.
When the actuator is inserted to an interlock switch in the dif-
ferent direction from the open/close direction of the door, do
not open the door with excessive force, otherwise failure or
damage will be caused.
When an operator enters the hazardous zone, take a safety
measure such as using padlock hasp HS9Z-PH5 so that the
operator is not trapped inside and the machine is not operated
while the operator is in the hazardous zone.
Do not install the sliding actuator as shown below, otherwise
the actuator may be removed from the interlock switch due to
shocks.
Ensure to slide the sliding actuator completely. Incomplete in-
sertion of the actuator may cause unstable contact operation
of the interlock switch. Also, door may not be opened, damag-
ing the actuator.
Do not close the door when the actuator is slid out of the cov-
er, otherwise the actuator may damaged.
When using the sliding actuator, take care so that fi ngers
or hands are not caught between the actuator and interlock
switch.
(08/03/12)
Two Oblong
Mounting Holes
5
4
HS5B/5E Sliding Actuator
When using with HS5E interlock switch
106
HS5E
Interlock
Switch
Thickness Adjustment Plate
(to be provided by the user)
Recommended thickness:
Fasten the actuator cover on at least two rectangular holes
and two round mounting holes using mounting screws.
The thickness adjustment plate requires mounting holes.
When installing the sliding actuator over
the interlock switch as shown below, do
not apply a shock exceeding 100 m/s
to the actuator, otherwise the actuator
may be inserted to the interlock switch
and cause unintended machine opera-
tion.
Use the sliding actuator with HS5B and
HS5E interlock switches only. Do not
use with other products.
Do not modify or disassemble the slid-
ing actuator.
Adjustment
1.
Mounting Reference Position
The mounting reference position of sliding actuator is shown
below.
Mounting
Position
Tolerance: ±2.5
26.7
2.
Recommended Tightening Torque of Mounting Screws
M5 screws for mounting the sliding actuator: 4.5 to 5.5 N·m
M4 screws for mounting the interlock switch: 1.8 to 2.2 N·m
Note: The above recommended tightening torque of the mounting screws are
the values with hex socket head bolts. When other screws are used
and tightened to a smaller torque, make sure that the screws do not
become loose after mounting.
Two Oblong
Mounting Holes
4
Two Round
36.2
5
Mounting Holes
0
5 mm
-1
HS9Z-SH5
2
Interlock
Switch
HS5B Interlock Switch
+3
21
4 (Mounting position tolerance 4 )
-1