Kayoba 650460 Operating Instructions Manual page 34

Bilge pump
Table of Contents

Advertisement

Available languages

Available languages

EN
1.
Connect a hose with a 19 mm ID to the outlet connector and
secure with a stainless steel clip.
2.
Place the hole for hose routing through the hull at least 30 cm
above the waterline, to prevent water from entering when the
pump is turned off.
Cable routing
NOTE:
• Use cables with a cross sectional area of at least 1.3 mm².
• If the pump is placed more than 6 m from the battery, the cables
must have a cross sectional area of at least 2.1 mm².
• Conductors with a too small cross section can overheat and cause a
voltage drop and reduced pump capacity.
1.
Place all cable connections as high as possible from the water
level. Protect using a marine-approved sealant.
2.
Secure the cables with insulated clips or plastic cable ties.
3.
Fit the positive cable from the battery with a fuse.
4.
Connect the pump's brown connector to the positive battery
terminal. The pump must be connected with the correct polarity,
otherwise it will run backwards.
34
The panel switch with integrated fuse holder can be used.
Only use a fuse of the correct size.
Min. 30 cm