10.3 Mechanical remote RESET

10.3
Mechanical remote RESET
Available versions
A mechanical remote reset option is also available for thermal overload relays and solid-
state overload relays. There are two options for mechanical remote RESET:
● Release slide (Page 90)
● Cable release with holder for built-in overload relays which are hard to reach (Page 92)
10.3.1

Release slide

10.3.1.1

Description

Release slide
There is one release slide for thermal overload relays and one for solid-state overload relays;
both are compatible for use with all sizes. The release slide with holder and former is used to
activate the RESET from the control cabinet door; it is shortened to the required length. A
pushbutton with extended travel and an extension plunger for compensation of the distance
between the pushbutton and the relay's unlocking button are available for the release slide.
90
SIRIUS Innovations - SIRIUS 3RU2 thermal overload relays / SIRIUS 3RB3 solid-state overload relays
Manual, 09/2014, A5E03656507420A/RS-AA/002

Hide quick links: