1. Relief pressure plus maximum allowable build-up over setting.
2. The pressure/temperature limits in this instruction manual and any applicable standard or code limitation for this relief valve should not be exceeded.
RElIEF SET PRESSuRE
10 to 18 psig
(0,69 to 1,2 bar)
18 to 30 psig
(1,2 to 2,1 bar)
30 to 100 psig
(2,1 to 6,9 bar)
MAIn VAlVE SPRIng,
PART nuMBER,
SET PRESSuRE
AnD COlOR,
RAngE, PSIg (bar)
PSIg (bar)
For set pressures
(0,69 to 1,2)
up to 30 (2,1)
1F826927052
Pink
(1,2 to 2,1)
For set pressures
over 30 (2,1)
30 to 100
1D751527022
(2,1 to 6,9)
Unpainted
1. Set pressure is defined as the pressure at which the pilot exhaust starts to bubble (discharge).
2. Crack pressure is the inlet pressure at which the main valve starts audible flow.
3. Inlet pressure buildup over the set pressure to achieve wide-open capacity.