3. INITIAL OPERATION

Insert battery [ Fig. I1 / I2 ]:
The Water Control must only be operated with
a 9 V alkalimanganese (alkaline) battery type
IEC 6LR61.
(16)
1. Remove controller
Water Control.
2. Insert battery in the battery compartment
Observe correct polarity
The display shows all the LCD-symbols for
2 seconds and then moves to the time / day
of week level.
(16)
3. Install controller
on the housing again.
Set display to 24-hours or 12-hours (am / pm):
The factory setting is the 24-hour display.
v Press the Man. button continuously while
inserting the battery.
To connect the Water Control [ Fig. I3 ]:
The Water Control is fitted with a sleeve nut
taps with (G 1") (33.3 mm) thread. The adaptor
supplied
(18)
allows the Water Control to be con-
nected to taps with a (G 3/4") thread (26.5 mm).
1. For tap with a G 3/4" (26.5 mm) thread:
Screw adaptor
(18)
on to the tap manually
(do not use pliers).
2. Screw sleeve nut
(19)
the adaptor thread by hand (do not use pliers).
3. Screw Tap Control
(20)
outlets.
Connect the soil moisture sensor (optional):
In the case of rain, or when the soil is sufficiently
moist, a programmed, automatic watering pro-
gramme will be stopped or prevented from start-
ing. Manual operation is possible at all times.
16
1 Bar
Battery low
Valve opens.
The Water Control will
continue to work for no
more than 4 weeks.
It is advisable to change
the battery.
v Replace battery (see 3. INITIAL OPERATION Inserting battery).
from the housing of the
(17)
(P)
.
(19)
of the Water Control on to
onto the two Water Control
0 Bar
Battery almost flat
Valve still opens.
The Water Control stops
working soon.
The battery must be
changed soon.
Sensor assignment [ Fig. I4 ]:
(a)
A sensor in Connector 1:
Sensor only applies to Valve 1
(b)
A sensor in Connector 2:
Sensor applies to both valves
(c)
Sensor in Connectors 1 and 2:
Sensor 1 applies to Valve 1
.
Sensor 2 applies to Valve 2
1. Place the soil moisture sensor in the watering
area.
2. Remove controller
Water Control.
3. [ Fig. I5 ]: If necessary, connect sensor to
Extension Cable or Adaptor at the sensor
(21)
connection
Activate sensor [ Fig. I6 ]:
A sensor will be automatically activated after 60 sec.
The sensor assignment
current sensor status dry / wet will be displayed.
E. g. Sensor 1 dry (dry) Valve 1
for
Deactivate sensor [Level 6]:
If watering is to be without a sensor, although
a sensor was previously activated, then this sensor
must be deactivated.
1. Remove sensor from the Water Control.
2. [ Fig. I6 ]: Press Menu button 5 times [Level 6].
The sensor assignment
and the current sensor status dry / wet will be
displayed.
3. [ Fig. I7 ]: Press OK button.
The sensor has been deactivated.
To connect older sensors (with 2-pin connector),
the GARDENA Adapter Cable
Art. 1189-00.600.45 is required, which can
be procured from GARDENA Service.
Frame is flashing
Battery flat
Valve does not open.
The Water Control stops
working.
The battery must be
changed.
(16)
from the housing of the
of the Water Control.
(a)
,
(b)
or
(c)
(arrow) and the
(a)
only.
(a)
,
(b)
or
(c)
(arrow)