Retrieving the starting time delay (F2+F4)

You can retrieve the set starting time delay of the hygiene flush (F2 + F4).
> Press the F2 and F4 buttons once simultaneously to retrieve the starting time delay.
The status LED flashes on the membrane keypad according to the steps that are set
(see table 1: Hygiene flush) and then lights up constantly for approx. 5 sec.
If the LED flashes 5 times after pressing the F2+F4 buttons (starting time delay), the
starting time is delayed by 20 h (5x4 h).
Activation status (F2)
Flush duration per flush
(F1)
Flush packages per hygiene
flush (F3)
Interval time (F4)
Starting time delay (F2+F4)
Table 1: Hygiene flush

6.4 Setting the hygiene flush

Activating/deactivating the hygiene flush (F2)

You can activate the hygiene flush and also deactivate it again.
> Press and hold the F2 button and press "+" once.
The status LED flashes twice on the membrane keypad. A flush is triggered after
approx. 10 sec. The hygiene flush is activated.
> Press and hold the F2 button and press "-" once.
The status LED flashes once on the membrane keypad. The hygiene flush is deactivated.
The settings you make via the membrane keypad remain unchanged as long as pow-
er is available (see 7 Power failure), even if you deactivate the hygiene flush. You can
activate the hygiene flush, for example when you go on holiday, and deactivate it again
when you return.
Factory settings
Deactivated
Approx. 6 sec.
1 flush
72 h
0 (counts as a step)
Setting range
Activated/deactivated
Approx. 2 to 10 sec.
(9 steps)
1 to 10 flushes
(10 steps)
24 h, 48 h, 72 h...to 240 h
(10 steps)
0, 1, 2, 3, 4, 5
(in 4 h steps)