Advertisement

Quick Links

WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment
by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or
local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation
and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all
warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can
cause serious injury, property damage, or death. For installations in the vicinity of occupied/living spaces, as an additional measure
of safety, Zodiac Pool Systems LLC strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this
appliance and in any adjacent occupied spaces. Improper installation and/or operation may void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
MAINTENANCE MANUAL
Grand Effects
IF THESE INSTRUCTIONS ARE NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT,
CAUSING PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH.
OPERATION AND
Manual Operation
®
Fire Pits

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPGCORCOP40 and is the answer not in the manual?

Questions and answers

Summary of Contents for GRAND EFFECTS FPGCORCOP40

  • Page 1 OPERATION AND MAINTENANCE MANUAL Grand Effects ® Fire Pits Manual Operation IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, WARNING CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists.
  • Page 2: Table Of Contents

    Section 1. Important Safety Instructions ..3 Section 2. General Description ...... 4 Product Overview ............4 Product Contents............4 Section 3. Installing the Grand Effects ® Fire Pits .......... 5 Preparing the Fire Pit for Installation ......5 Gas and Electric Requirements........7 Installing the Fire Pit ............7...
  • Page 3: Section 1. Important Safety Instructions

    Visit www.zodiacpoolsystems.com for additional free copies of these instructions or call Zodiac Technical Support at 800.822.7933 (U.S.) or Grand Effects at 949.697.5270 ATTENTION INSTALLER This manual contains important information about the installation, operation and safe use of this product.
  • Page 4: Section 2. General Description

    ® CAUTION The Grand Effects Fire Pits are not serviceable and therefore contain no serviceable parts. In order to prevent risk of property damage and/ or injury, no service should be attempted to the fire pit in the event of a malfunction.
  • Page 5: Section 3. Installing The Grand Effects

    The approved gas valve must be located where they can be easily accessible so that the gas can be shut off quickly in case of an emergency. Install the following Grand Effects Fire Pit (42”- 60”Biltmore) as shown in Figure 1 or Figure 2.
  • Page 6 Page 6 Fire Pits Manual Operation 48”Essex and 45”Cielo and 42” Legacy require a Grand Effects ® Mounting Bracket to be installed. The Mounting Bracket secures bowl and allows for cooling air and water drainage. Install the mounting bracket as shown in Figure 3. The mounting bracket should be secured using three bolts.
  • Page 7 Fire Pits Line Manual Operation Page 7 The piping must be reduced to ½″ NPT or larger at the burner, as shown in Figure 2. At the burner assembly, install a 90° gas pipe elbow on the gas line for proper installation of a gas hose. Do not kink or make a tight radius bend on the gas hose.
  • Page 8: Section 4. Burner Setup And Adjustment

    Page 8 Fire Pits Manual Operation Section 4. Burner Setup and Adjustment Note: Each burner should have a flame height of approximately 12″ – 15″ from the top of the bowl. The height of the flame can be adjusted at each burner by opening or closing the ½″...
  • Page 9: Section 5. Maintenance

    The burner should not be operated in high wind conditions. BOWL MOUNTING BRACKET Figure 3. Maintenance Important: Gas must be securely shut off when not in use. Note: If any problems are present, consult a licensed heating specialist or call Grand Effects.
  • Page 10: Section 6. Operation

    • Before any inspection of the unit, always turn off power and gas supply at the control panel. • If you experience problems with this unit, call Grand Effects or a licensed heating professional. All work on this unit must be performed by a licensed heating professional.
  • Page 11 Fire Pits Line Manual Operation Page 11 NOTES...
  • Page 12 Grand Effects 23121 Arroyo Vista, Suite B, Rancho Santa Margarita, CA 92688 1.949.697.5270 | www.GrandEffects.com Zodiac Pool Systems LLC 2882 Whiptail Loop #100, Carlsbad, CA 92010 1.800.822.7933 | www.ZodiacPoolSystems.com ©2020 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

This manual is also suitable for:

Fplegcon42

Table of Contents