  • Page 2 Installation and General Information: DO NOT WALK OR STAND ON TOP OF DRAWERS FOR ANY REASON or damage to the case and serious personal injury could occur. THEY ARE NOT STRUCTURALLY DESIGNED TO SUPPORT EXCESSIVE EXTERNAL LOADING such as the weight of a person. Handling of Griddle stand ●...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Notice Product Specification Sheet Technical Date RB36 Technical Date FB36 Technical Date RB48 Technical Date FB48 Pan Layouts Options General Preventive Maintenance Periodic Cleaning Procedure Troubleshooting Chart Troubleshooting Chart Cont. Warranty SP8143-2008...
  • Page 4: Product Specification Sheet

    PRODUCT SPECIFICATION SHEET AIR FLOW CORD & PLUG AT REAR THERMOSTAT RMV FRONT PANEL RMV SIDE PANEL FRONT BRAKES SP8143-2008...
  • Page 5 Technical Data RB36 Model No. ( REFRIGERATION ) Length 35.625" Height with casters 27.25" Depth 33.75" Operating temperature 37°F to 40°F Refrigerant (expansion valve) R404A Compressor size HP Defrost per day (24 hours) Auto Voltage Amperage Cord and plug - Condensing Unit...
  • Page 6 Technical Data Model No. ( FREEZER ) FB36 Length 35.625" Height with casters 27.25" Depth 33.75" Operating temperature 0°F to 3°F Refrigerant (expansion valve) R404A Compressor size HP Defrost per day (24 hours) Voltage Amperage Cord and plug - Condensing Unit L5-15P Number of drawers SP8143-2008...
  • Page 7 Technical Data RB48 Model No. ( REFRIGERATION ) Length 47.625" Height with casters 27.25" Depth 33.75" Operating temperature 37°F to 40°F Refrigerant (expansion valve) R404A Compressor size HP Defrost per day (24 hours) Voltage Amperage Cord and plug - Condensing Unit L5-15P Number of drawers SP8143-2008...
  • Page 8 Technical Data FB48 Model No. ( FREEZER ) Length 47.625" Height with casters 27.25" Depth 33.75" Operating temperature 0°F to 3°F Refrigerant (expansion valve) R404A Compressor size HP Defrost per day (24 hours) Voltage Amperage Cord and plug - Condensing Unit L5-15P Number of drawers SP8143-2008...
  • Page 9 PAN LAYOUTS (FULL SIZE PANS OPTIONS) Please note - each drawer is only supplied with one pan rail as standard. More pan rails can be purchased separately to create all layouts seen above. SP8143-2008...
  • Page 10: General Preventive Maintenance

    General Preventive Maintenance Performance of the air cooled condenser coil located inside condensing unit compartment of your new unit depends primarily on the amount of air passing through the condenser fins. 1. Your case will run more efficiently, consume less energy, and provide maximum trouble free service throughout its lifetime if the condenser is kept clean and an adequate supply of clean air is provided at all...
  • Page 11: Periodic Cleaning Procedure

    Periodic Cleaning Procedure It is best to clean your unit when the product load is at its lowest level. To clean the interior or exterior cabinet surfaces, the following procedure is recommended: 1. Disconnect your unit from its power supply and remove all food products from inside the drawers.
  • Page 12 Precautions 1. Never use harsh detergents, cleaners, scouring powders, or chemicals when cleaning your unit. 2. Strong bleaches tend to corrode many materials and should never come in contact with stainless steel. 3. Tincture of iodine, or iron should not come in contact with stainless steel.
  • Page 13: Troubleshooting Chart

    Troubleshooting Chart SP8143-2008...
  • Page 14: Troubleshooting Chart Cont

    Troubleshooting Chart Cont. SP8143-2008...
  • Page 15: Warranty

    During the warranty period, AccuTemp agrees to repair or replace, at its option, F.O.B. factory, any part which proves to be defective due to defects in material or workmanship, provided the equipment has not been altered in any way and has been properly installed, maintained, and operated in accordance with the instructions in the AccuTemp Owner’s Manual.
  • Page 16 This warranty is exclusive and in lieu of all other warranties expressed or implied, including any warranty of merchantability and fitness for a particular purpose. AccuTemp does hereby exclude and shall not be liable to purchaser for any consequential or incidental damages.
  • Page 17 P49-1010 4" CASTERS 250 LBS CAPACITY 4" CMPI-3PPB 4" CASTERS 250 LBS CAPACITY 4" CMPI-3PBB W/BRAKES ACCU TEMP GRIDDLE STAND 36" X 33.75" GAS & ELECTRIC MODEL: RB36 PART DESCRIPTION MODEL NO. EVAPORATOR COIL BBM 11 EXP. VALVE 404A EFS1/4-C...
  • Page 18 ACCU TEMP GRIDDLE STAND 48" X 33.75" GAS & ELECTRIC MODEL: FB48 PART DESCRIPTION MODEL NO. EVAPORATOR COIL BBL 10 EXP. VALVE 404A EFS1/4-C ZP CONDENSING UNIT 1/4HP-404 M6TL-0037-IAA-177 FILTER DRYER C-052-S SITE GLASS SA-12-S DIGITAL TEMPERATURE CONTROL 318-9316 TEMPERATURE CONTROL PROBE 2013012 MAGNETIC GASKETS 31-1/16X7-13/16...
  • Page 20 SP8143-2007 SP8143-2008...
  • Page 21 SP8143-2007 SP8143-2008...

This manual is also suitable for:

Fb36Rb48Fb48