AccuTemp EDGE ALTEH-5 Owner's Manual And Installation Instructions

Insulated self-contained tilting table-top, electric

Advertisement

Quick Links

INSULATED SELF-CONTAINED TILTING TABLE-TOP, ELECTRIC
OWNERS MANUAL AND INSTALLATION INSTRUCTIONS
Models: ALTEH-5 and ALTEH-10
MODEL ALTEH-10
Made in U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for AccuTemp EDGE ALTEH-5

  • Page 1 INSULATED SELF-CONTAINED TILTING TABLE-TOP, ELECTRIC OWNERS MANUAL AND INSTALLATION INSTRUCTIONS Models: ALTEH-5 and ALTEH-10 MODEL ALTEH-10 Made in U.S.A.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Uncrating and Inspecting the Equipment Installation Electrical Connection Water Fill Connection Operation Kettle Venting Instructions Maintenance Service Re-Calibrating Thermostats Primary Thermostat Replacement Heating Element Replacment Trouble-Shooting Illustrations Caring for Stainless Sanitizing Parts List Wiring Diagrams 208-240 Volt /3Ph Delta Models ALTEH-5 & 10 GAL. 440, 460 &...
  • Page 3: Uncrating And Inspecting The Equipment

    Careful inspection of the packaging and the appliance should be completed before acceptance from the transportation company. CONTACT INFORMATION: Toll Free 800 480-0415 Office 260 469-3040 Fax 260 469-3045 Email - Service service@accutemp.net Email - Parts parts@accutemp.net Web Site www.accutemp.net...
  • Page 4: Installation

    INSTALLATION Once the unit has been removed from its shipping container, it should be inspected for damage that may have occurred while in transit. Immediately notify the carrier if any damage is found. 1. Provide minimum clearances as per table below. 2.
  • Page 5: Operation

    Appliance failure caused by inadequate water quality is not covered under warranty. Caution: Drain the steam jacket if the kettle is to be stored in an unheated area. Water freezing in the steam jacket may cause damage to the unit. OPERATION AILY PERATION...
  • Page 6: Maintenance

    1. With the temperature control knob set at 230°F, heat the empty kettle until the vacuum/pressure gauge indicates 5-10 psi. Caution - do not exceed 5 - 10 psi. Opening the safety valve at higher pressures is a severe burn hazard.
  • Page 7: Re-Calibrating Thermostats

    If the thermostat is defective or not working properly, it must be replaced (without breaking the seal) and returned to Accutemp. The warranty is voided if the seal is broken or an attempt is made to recalibrate the thermostat. See below for replacement instructions of the thermostat.
  • Page 8: Heating Element Replacment

    before you have the capillary tube and thermobulb in its final position. Once thermobulb and capillary are in their final position, you are ready to secure the thermobulb and capillary tube in place. 13 Coat the outer threads only of the 3/8” hex pipe plug (the large plug) with Teflon pipe sealant. Thread this hex pipe plug into the weld coupling securely.
  • Page 9: Illustrations

    Symptoms What to check for… Rapid clicking noise (chattering) Voltage, to see if it is too low* Contactor, for dirt or corrosion on the contacts* Uneven cooking due to “cold spots” For burned out (open) or loose heating elements.* See Service section for test and replacement procedures. ILLUSTRATIONS Safety Relief Valve, Pressure Gauge, Pigtail...
  • Page 10: Caring For Stainless

    Caring For Stainless Steel This section provides specific guidelines for cleaning and protecting the stainless steel surface of your equipment. Important! Always disconnect power before cleaning (or servicing) the unit. Never spray the control console, electrical controls, gas controls, or connections with water. Clean these areas by wiping them with a clean, damp cloth. The stainless steel can be cared for using any good commercial stainless steel cleaner or polish.
  • Page 11 Caring For Stainless Steel 6. To remove stuck materials, use a brush, sponge, cloth, plastic or rubber scraper, or plastic wool with the cleaning solution. To reduce effort required in washing, let the detergent solution sit in the unit and soak into the residue.
  • Page 12: Parts List

    Parts List Part Number Description 407998 Primary thermostat 407998-D-1 Dial, primary thermostat 407793 Grommet, thermostat shaft 407451 Indicator light red 240v 407452 Indicator light amber 240v 430085 Tilt switch 20 amp, 240 volt 440280 Siphon (pigtail) ¼” npt 456725 Safety valve 50 psi / 625 lbs/hr 456727 Pressure gauge 30Hg-0-60 405296...
  • Page 13: Wiring Diagrams

    Wiring Diagrams...
  • Page 14: 440, 460 & 480 Volt/3Ph Delta Models Alteh-5 & 10 Gal

    Wiring Diagrams...
  • Page 15: 380, 415 Volt /3Ph Delta Models Alteh-5 & 10 Gal

    Wiring Diagrams...
  • Page 16: Maintenance And Service Log

    Maintenance & Service Log Model No.: Purchased From: Serial No.: Date Purchased: Purchase Order No.: Location Installed: Date Installed: Date Maintenance Performed: Performed By:...
  • Page 17: Product Warranty

    One Year Parts and LaborOne Year Parts and Labor AccuTemp Products, Inc. ( AccuTemp ) warrants that your AccuTemp equipment will be free of defects in material and workmanship under normal use for a period of twelve (12) months from installation or fifteen (15) months from date of shipment from AccuTemp, whichever date first occurs (the Warranty Period ).
  • Page 18 IMPORTANT SERVICE INFORMATION AccuTemp Product, Inc. Technical & Customer Support Technician is available Monday thru Sunday, 7:00am to 7:00pm EST.