Trigger Mode
In all modes, the only command that can be sent when the laser is on is the Turn Laser Off
command. Select one of the following options:
Level Trigger - A trigger pull or external switch closure activates the laser and
decode processing. The laser remains on and decode processing continues until
a trigger release, a valid decode, or the Laser On Time-out is reached.
Host - The host sends a Laser On command. The laser remains on and decode
processing continues until a good decode, the Laser On Time-out is reached, or
the host sends a Laser Off command. External trigger acts as a Level trigger in this
mode.
Pulse - A trigger pull activates the laser and decoding processing. The laser
remains on and decode processing continues until a valid decode or the Laser On
Time-out is reached.
Constant Scan & Report - Laser is always on and decoding. This option is not
recommended when programming the scanner with bar code menus.
Next New Code - The LS 1220 decodes and transmit information, then waits until
a new code is detected before transmitting again.
Continuous Level - The laser is always on. Decode processing begins with a
trigger pull and continues until a trigger release, or the Laser On Time-out is
reached.
Continuous Pulse - The laser is always on. Decode processing begins with a
trigger pull and continues until the Laser On Time-out is reached.
Laser On Time-out
The maximum time the laser remains on or decode processing continues during a trigger
pull. Programmable in 0.5 second increments from 0.5 to 4.0 seconds.
Laser Off Time-out
The minimum time between decodes of the same symbol when in Constant Scan and
Report mode. Programmable in 0.5 second increments from 0.0 to 3.5 seconds.
Programming