Carrier Interface; Land-Based Carrier; General Engineering Considerations - Nortel Meridian 1 Manual

Remote peripheral equipment
Table of Contents

Advertisement

Carrier interface

Land-based carrier

General engineering considerations

The SL-1 RPE hardware interfaces with LD-1 carrier apparatus, which
conforms to the T1 industry standard. Therefore, any carrier system
conforming to T1 signaling standards should be able to interface with SL-1
RPE. Minor differences in carrier maintenance can generally be
accommodated by option switches in the carrier interface card.
In addition to the T1 carrier rules, the following standards apply:
— The distance from local to remote equipment cannot exceed 112.7 km
(70 mi).
— Line repeaters are powered from the office repeater bay (ORB), since no
power is available from the SL-1 interface.
— The SL-1 interface with the LD-1 carrier line contains an M-type
fault-location filter (3017 Hz) without level-of-polarity options. The FL
filter is powered by the SL-1 RPE equipment. No other M-type filters can
be used in the same span.
RPE Description, installation, and testing
Page 35 of 60