Duo 1, 2, 4, 5, 6 Monterings- og bruksanvisning Installations- och bruksanvisning Installation- and user manual Käyttöohje Montageanleitung Manuel d’installation Product no: 44665543/ 44665562/ 44665577/ 44665581/ 44665596/ 696165 Test no: RRF-40 11 2892, RRF-40 11 2893, SP PX14432-A, SP PX14432 Last updated: 28.09.2017...
Page 2
INDEX 1. Please follow the installation manual when Chimney Draught Air Supply 2. Technical Information pipe to the surrounding materials. 2. Before use, please carefully read the user manual and follow the instructions. Operating Control Installation of Thermotte™ Adjustment of Legs never be reduced or partially obstructed.
All safety distances are minimum distances. Installation of the Important to check stove must comply with the current rules and regulations of the country where the product is installed. Nordpeis AS is not (please note that this list is not exhaustive): •...
Remove the 4 plastic lids and adjust the legs with a 17 mm wrench. Put the plastic lids back in place. Duo 1: Remove the lid that covers the rear of Flue outlet collar the pedestal with a 10 mm wrench, unfasten the transportation lock.
Air 1, 2 and 4/5/6. The CE-mark which is included should be placed on the are inserted into a hot burn chamber. Let the stove. Duo 1: The CE mark should be placed on the oblique surface behind the stove. FIG 12.
Page 6
Please note: Wood logs that are too long can cause are prohibited. strain and crack the plates, due to the tension created between the side plates. www.nordpeis.com Should there be any soot on the glass it may be necessary to clean it. Use dedicated glass cleaner, as other detergents may damage the glass.
Page 7
In order to ensure that the wood is dry, the tree should be cut in winter and stored during the summer, covered and in a location with adequate ventilation. The wood pile must never be covered by a tarpaulin lying on the ground as the tarpaulin will then act as a sealed lid that will prevent the wood from drying.
Page 8
se of combustion problems Error Explanation Solution The chimney is blocked Contact a chimney sweeper / dealer for more information or clean Downdraught in the room caused by no draught, that the must be installed in the room. Downdraught in the room – caused by extractor and/or central ventilation system that pulls too much air out of more vents must be installed.
Page 24
PLASSERING AV SERIENUMMER / PLACERING AV SERIENUMMER POSITION OF THE SERIAL NUMBER / SARJANUMERON SIJAINTI POSITION DER SERIENNUMMER / POSITION DU NUMÉRO DE SÉRIE...
Page 26
Permanent pilot flame power requirement Pilot flame power requirement (if applicable) Contact details Name and address of the supplier: Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway...
Page 27
Nordpeis AS. Nordpeis DUO ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE 2015/1186 Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway www.nordpeis.no...