6. Check if the oil pressure is ok, and then adapt the speed handle gradually to make the
speed meet 75%~80% of the standard speed. Then run without load.
5.7 Running the Engine
1. Only when the temperature of the cooling water reach 50~60℃ and oil temperature
reach 40~50℃, can operate the engine with load. When the water temperature reaches
80℃, operate the engine at full load. You can reduce the speed of the engine, engage
the load and accelerate again, slowly to the rated speed.
2. The engine speed and load should be increased and decreased gradually. In general,
shouldn't increase and decrease rapidly.
3. When the engine is working, should pay attention to each data of the meter and observe
the color of the exhaust smoke, listen to the voice inside. If any problem appears,
should stop the engine immediately and calla the technical support.
4. It is not recommended to let the engine run at idle speed for long time. Warming up and
cooling down period should not exceed max. 5 min.
5. Do no run the engine with load, at idling speed, for more than 1 min.
5. The injection pump has been adjusted rightly before leaving factory, it is forbidden for
user to change it at will. If necessary, call the technical support.
Note: New diesel engine or just overhauled engine, it is permitted to run at full load
only after it has worked over 60 hours!