42 in. 2-speed heavy duty belt drive drum fan (6 pages)
Summary of Contents for Commercial Electric CE-15
Page 1
THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this Industrial 15 ft HVLS fan. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home...
Table of Contents I Beam/Truss ........10 TABLE OF CONTENTS .
Page 3
Ensure that all safety practices and instructions are followed during the installation, operation and servicing of the fan. Failure to apply these safety practices could result in death or serious injury. If you do not understand the instructions please call the Commercial Electric Customer Service.
Page 4
Commercial Electric provides guidelines for mounting fans; however, it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system, that the building structure is sound and that the installation complies with all federal, state, and local codes.
Warranty Information The manufacturer extends this warranty to the original retail purchaser of its model or, if this unit is purchased and installed by a building contractor, then to the original owner of the building. No subsequent purchaser of the unit or of a building which it is installed is entitled to any of the benefits of this warranty.
Pre-Installation PLANNING INSTALLATION Prior to installation, make sure to read the entire Use and Care Guide and observe all requirements specified. NOTE: For any application not explicitly covered in this Use and Care Guide, please consult a structural engineer. TOOLS REQUIRED Flat Blade Phillips Level...
Pre-Installation PACKAGE CONTENTS Part Description Quantity Guy Wires Fan Blades Guy Wire Band Fan Motor Unit Mount Safety Cable...
Page 9
Pre-Installation FAN SPEED NEMA 4X/IP65 Part Description Quantity VFD/Control Box Cable To The Incoming Power Cable To The Motor HOMEDEPOT.COM Please contact 1-877-527-0313 for further assistance.
Installation – I-Beam/Steel Truss Secure the I-Beam Clamp Position the Top Plate □ Position the top plate under the I-beam so that one side of FOR MOUNTING TO STEEL TRUSSES OVER the beam is between the clamp and top plate. 3 INCHES IN WIDTH.
Installation – Motor Unit Slide in the Drop Attachment Secure the Frame □ Slide the drop attachment point of the frame into the drop □ Secure the frame to the drop tube with two (2) motor tube of the mount, ensuring that the bolt holes line up. attachement bolts and nuts with four (4) washers.
Installation – Safety Cable Wrap the Safety Cable Secure the Safety Cable Clamps □ Secure two (2) safety cable clamps around the wire. Pull WARNING: DO NOT PUT TOO MUCH TENSION the cable taut and tighten both nuts using a 10mm wrench. ON THE SAFETY CABLE.
Installation – Guy Wires Secure the Guy Wires Secure the Guy Wires to the Building □ Secure the four (4) guy wires to the attachment points on □ Secure the four (4) guy wires to the building structure so the frame. that the guy wires are at a 45 degree angle from the drop and 90 degrees from each other.
Page 14
Installation – Guy Wires Insert the Guy Wire Band Pull the Cords through the Cable Lock □ Insert the guy wire band through the top eyelet of each of □ Pull one of the ends of the cord through one of the holes on the four (4) turnbuckles.
Installation – Blades Apply the Provided Lubricant Slide the Blades onto the Blade Struts □ Apply the provided lubricant in 4 spots on the top and □ Slide the blades onto the blade struts and align the holes in bottom of each strut. Each line of lubricant should be in the blade and the blade struts.
Electric Code (NEC) 2005, ANSI/NFPA 70-1999, and all local codes. This fan control should only be installed by qualified technicians familiar with the requirements of the NEC and local codes. Note: Commercial Electric has a policy of continuous product improvement and reserves the right to change the design and specifications without notice.
Page 17
Installation: Electrical Feed the Cable through the Frame Attach motor cable to VFD □ Feed one end of the 50’ cable to the motor through the top □ Attach the other end of the 50’ cable to the receptacle on of the frame and plug it into the receptacle on the frame.
Operation FAN SPEED Select forward direction for cooling or Turn the VFD on reverse for destratification (heating) NEMA 4X/IP65 Adjust the speed dial to control how fast the fan rotates NEMA 4X/IP65 FAN SPEED...
Annual inspections from a lift and seasonal inspections both before and after the busy season from the ground. NOTE: If there are issues or concern discovered during an inspection, please contact the service and Commercial Electric Customer Service for help.
Confirm that there is nothing interfering with any moving parts. The fan is wobbling. Confirm that the fan is level and the guy wires are properly installed and tightened. If your issue cannot be resolved using the table above, please call Commercial Electric Customer Service: 1-877-527-0313.
Service Parts MODEL TYPE FAN SPEED NEMA 4X/IP65 I, J Part Description Quantity Part Description Quantity Complete Power Unit Retainer Links 15’ Diameter Blade (78 ¾”) Retainer Links Set of 5 15’ Diameter Blade Set of 5 Mount Bolt Kit (78 ¾”) Blade Bolt Kit Extension...
Page 22
Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST, Saturday 1-877-527-0313 HOMEDEPOT.COM Retain this manual for future use.
Need help?
Do you have a question about the CE-15 and is the answer not in the manual?
Questions and answers