UTD2000M User Manual
Function
Bandwidth Limit
Vertical Scale Coefficient
Volts/Grid
Phase Reversed
Horizontal Position
Second/Grid
Acquiring Mode
Sampling Mode
Fast Sampling
Trigger Type
Trigger Signal Source
Trigger Coupling
Trigger Mode
Hold Off
Trigger Level
Slope Type
Signal Identification
Remarks:
The adjustment of trigger signal source while the Unit is in "AUTO" is based on the following points:
1. If only one channel has input signal, then set the signal input channel as the trigger source.
2. When more than one channel are used, the auto setting function sets the vertical control of each channel
and uses the active channel with minimal number to set horizontal and trigger control.
3. If no signal has been found in all channels, then use CH1 channel as the trigger source.
2.11.2 Auto (Auto Settings) Strategy
In actual use, many times, we hope the unit is able to auto set itself the way we want it be. In this sense, auto (auto
Open
Full bandwidth
Adjust in accordance with signal
amplitude
Rough tuning
Close
Auto Adjustment
Adjust in accordance with signal
frequency
Normal sampling
Equivalent or maintain current
settings real‐timely
Close
Edge
According to signal of CH1 or CH2, see
remarks
Maintain current setting while the
unit is in DC, AC, Low frequency reject
or high frequency reject mode;
Auto
Minimum Value
Set to be 50%
Rising
Automatically adjust the channel
60
Lock
Full bandwidth or maintain current
settings of 20MHz.
Adjust in accordance with signal
amplitude
Rough tuning
Open, close or maintain current settings
Auto Adjustment
Adjust in accordance with signal
frequency
Maintain one current setting while the
unit is in normal sampling, peak value or
average state;
Equivalent or maintain current settings
real‐timely
Close
Maintain current setting while the unit
is in edge, pulse width, video or slope
triggering mode.
Maintain current setting while the unit
is in CH1, CH2, EXT, EXT/5 or AC Line
mode.
Maintain current setting while the unit
is in DC, AC, Low frequency reject or
high frequency reject mode;
Auto
Maintain current setting
Set to be 50%
Maintain current setting
Currently opened channel