Cooling Stage 1
Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at
Off Threshold
Cooling Stage 2
Sets the delta from setpoint that stage 2 cooling starts.
On Threshold
Cooling Stage 2
Sets the delta from setpoint that stage 2 cooling stops.
Off Threshold
Restore Defaults
Restores all settings to factory defaults. Press Yes to restore defaults
Factory Default
Please use this procedure only when the Z-Wave Primary Controller is missing or otherwise inoperable. To reset the
TBZ500's Z-Wave parameters to Factory Settings (both Z-Wave and HVAC settings):
1.
Remove power from the TBZ500.
2.
Restore power to the TBZ500.
3.
When "TBZ500" appears on the screen, hold down the MODE and FAN buttons at the same time.
4.
Release the buttons when RESET appears on the Status Line.
5.
Once the TBZ500 resets the Z-Wave and HVAC settings, a DONE confirmation message will appear on the screen before the thermostat self-reboots.
Copyright © Ecolink Intelligent Technology
TBZ500_manual_8_5x5_5_inch Combined_RDN1240221.indd 17
Description
setpoint - Delta Stage 1
Stage 2 turns off at setpoint - Delta Stage 2.
Press No to exit and not restore defaults
Range
Default
Setting
0 to 6 degrees
0
2 to 8 degrees
2
0 to 7 degrees
0
Y or N
N