Menu choices are displayed in
the Status Display Line.
Press "Select" to enter the
selected menu
Press "Done" to exit back to
the Main Thermostat Screen
Use the Up/Down buttons to
change to the desired menu item,
then press "Select"
Not sure which Changeover type?
Check the existing thermostat connections
to help determine this.
If the original system had an orange wire
connected to the "O" terminal, then this
is a "changeover with cool" system.
If there was a brown wire connected to
the "B" terminal, then this is a "change
over with heat" system.
Set the Change Over setting accordingly.
(Caution: These are typical wiring colors/
connections and may differ)
• I
f heating comes on when cooling is
expected or vice versa, change the
"Change Over Type" to the opposite
setting.
14
TBZ500_manual_8_5x5_5_inch
Combined_RDN1240221.indd 14

Thermostat Menu Screen

Menu Mode Navigation

When the thermostat Menu Screen is displayed, use the
Up or Down arrow buttons to scroll through the following
options:
Setup (user preference settings)
System (HVAC system setup)
Zwave (install/uninstall from Z-Wave network)
Info (firmware versions and Z-Wave network
information)
Select SYSTEM setup
To change the HVAC system default settings, use the down
arrow to progress to the SYSTEM menu item and press
"Select".

SYSTEM setup menu

The SYSTEM menu is used to set up the thermostat for the
correct HVAC system type.
System type
-
For Standard Gas/Electric systems, select "Standard".
This is the default setting.
-
For Heat Pump systems, use the Up/Dn arrows to
change to "Heat Pump"
-
Press Select to set.
-
Press Done to exit
Fan type (For Standard HVAC systems only)
-
Fan type depends on the heating system type.
-
For Gas heat: select "GAS". This is the default setting.
-
For Electric heat: use the Up/Dn arrows to change to
"ELECTRIC".
-
Press Select to set
-
Press Done to exit
Changeover type (For Heat Pump HVAC systems only)
The changeover (or reversing) valve is used to change from
heating to cooling operation. It is either a changeover with
cooling type (Orange wire) or changeover with heating
type (Brown wire). Most are changeover with cooling, which
is the default setting.
-
For Changeover with Cooling systems (Orange wire),
select "WITH COOL". This is the default setting.
-
For Changeover with Heating systems (Brown wire),
use the Up/Dn arrows to change to "WITH HEAT".
-
Press Select to set
-
Press Done to exit