SETUP AND CONFIGURATION, CONT.
LED A (SO= on Remote Display)
SWITCHED OPERATION MESSAGE SETTING
The SO = setting enables switched operation utilizing a customer supplied remote toggle
switch and does not require serial input to display the message pairs below. The
messages are driven from the current-loop input on the terminal block. Note that when
SO= is enabled (set to 1 to 9), the serial input to the SB250M is disabled. Also, note that
the factory default value is 0 (serial input is enabled).
The 7-segment LED (U15) and the scoreboard will show the current value. If the setting
displayed is acceptable, press the MODE switch to save it and advance to the next setup
parameter. Otherwise, using the (+) switch to increase the value or the (−) switch to
decrease the value, select the new setting, then press the MODE switch to save it and
advance to the next setup parameter. Values from 0 to 9 may be selected.
0 = DISABLED (Serial Input is Enabled)*
1 = OPEN
2 = GO
3 = ON
4 = START
* Factory Default
To use the switched operation, the Receive Mode jumper J4, must be
ON the CL pins. In addition, on the P1 terminal connector, jumper
terminals 6 and 7 together and then connect the operation toggle
switch across terminals 8 and 9. Refer to Figure No. 4 for the location
of J4, P1 and the connection descriptions.
LED B (SP= on Remote Display)
SUPPRESS LEADING ZEROS
The 7-segment LED (U15) and the scoreboard will show the current value. If the setting
displayed is acceptable, press the MODE switch to save it and advance to the next
setup parameter. Otherwise, using the (+) switch to increase the value or the (−) switch
to decrease the value, select the new setting, then press the MODE switch to save it
and advance to the next setup parameter. Values of 0 or 1 may be selected
0 = No suppression (DEFAULT)
LED A and B (SD= on Remote Display)
SUPPRESS DECIMAL POINT AT LOCATION 0 (ZERO)
The 7-segment LED (U15) and the scoreboard will show the current value. If the setting
displayed is acceptable, press the MODE switch to save it and advance to the next
setup parameter. Otherwise, using the (+) switch to increase the value or the (−) switch
to decrease the value, select the new setting, then press the MODE switch to save it
and advance to the next setup parameter. Values of 0 or 1 may be selected
0 = Allows a decimal point after the least significant digit of weight
1 = Prevents a decimal point from displaying to the right of the least significant
byte of weight (DEFAULT)
CLOSED
STOP
OFF
STOP
1 = Suppress zeros
3601-M481-O1 Rev C • SB250 Series
5 = WALK
WAIT
6 = LEFT
RIGHT
7 = UP
DOWN
8 = ENTER
EXIT
9 = SPACES (
) ASTERISKS (***)