REPAIR

5.1
Front & bottom access
Drain pump
Sump
Water valve
Float
The heat pump, drain pump, water inlet valve, junction box, aqua
sensor and float are accessible from the front & bottom.
5.2

Left side access

The water inlet system, condensation (breather) hose, water inlet
hose and internal drain hose are accessible from the left side.
702_58300000130262_ara_en_b
J-box
Heat
pump
5.3

Right side access (power module)

The power module is accessible from the right side.
Power module
Two plastic base tabs hold the power module in place.
remove power module, gently bend tabs until they clear module,
move bottom of module (in toward heat pump) until it clears base
and pull module from base.
Left (front) tab
Pulling bottom of
power module in
Up
toward heat pump
to remove module.
Up
Power module
Viewing from
Up
bottom, inside
To
Right (rear) tab
Up
Page 15 of 27