How to Time and Install the Countershaft Assemblies

Special Instructions
None
Special Tools
Typical service tools
Procedure -
1.
Mark the tooth which is stamped with an "O" on the reduction
gear of each countershaft.
2.
Place one of the countershaft assemblies in position inside
the plate with the marked tooth meshed between two of the
marked teeth on the reduction gear.