Maintenance Periodic inspection Periodic maintenance Friction material replacement Piston seal replacement Ordering information / Technical assistance Equipment reference Parts standard Rebuild kit 7 .1 Seat kit Revisions EATON Airflex DPA Caliper Brake Installation, operation and maintenance manual E-CLCL-II010-E October 2015...
Page 4
45DEG Elbow, 37DEG Flare X 1/8" NPT Male Air Bleeder M16X2.0 X 130 Hex Head Screw Flat Washer M16 X 2.0 Hexagon Nut Name Plate Warning Plate EATON Airflex DPA Caliper Brake Installation, operation and maintenance Manual E-CLCL-II010-E October 2015...
Friction shoes attach to the cylinders and are replaceable without disturbing the caliper mounting. Applying pressure to the cylinders piston causes the friction shoes to clamp the disc, developing the braking torque. EATON Airflex DPA Caliper Brake Installation, operation and maintenance manual E-CLCL-II010-E October 2015...
For hydraulically actuated systems, remove any air from the system by following instructions found in Section 4.2.1 later in this manual. Incorrect Correct Figure 3 EATON Airflex DPA Caliper Brake Installation, operation and maintenance Manual E-CLCL-II010-E October 2015...
0.315 inches, (8 mm), not including the damage it should be replaced. backing material. See table 2 for wear limits EATON Airflex DPA Caliper Brake Installation, operation and maintenance manual E-CLCL-II010-E October 2015...
Once the piston (2) has been removed, remove and discard the U seal (7) and rod wiper (8). Inspect the cylinder for any corrosion or pitting. If the cylinder EATON Airflex DPA Caliper Brake Installation, operation and maintenance Manual E-CLCL-II010-E October 2015...
Airflex DPA Caliper Brake Revisions Original Publication Date: 2007 Revision Date Description Page EATON Airflex DPA Caliper Brake Installation, operation and maintenance manual E-CLCL-II010-E October 2015...
Page 12
(12) months from the date of shipment to Purchaser, provided such Product is In no event shall Eaton be liable for special,incidental properly installed, properly maintained, operated under or consequential damages. Eaton’s liability arising out normal conditions and with competent supervision.