Vhf digital transceiver, uhf digital transceiver (4 pages)
Summary of Contents for Icom IC-F620
Page 1
Adjustment for IC-F620 ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Preparation Connect the transceiver by cloning cable (OPC-1122) to a PC (IBM compatible) and boot up the cloning software. Check points Be sure to use a tester with more than 50 kohm/V internal resistance when making each test.
Page 2
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point TX Output Use adjustment software to adjust the adjustment output to the values below. Adj.Soft Adj. Freq. Greatest Low Band Freq. Power Hi Power 25.0W 25.0W ANT Con L2 Power 10.0W 10.0W L1 Power...
Page 3
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Preparation for When there is no particular set limits, set Checking Modula- the modulation analyzer for adjustment and tion Adjustment checking as below. 20 kHz De-Emphasis Detector (P ± P)/2 Connect the modulation analyzer set at the above conditions, through the attenuator to the antenna terminal.
Page 4
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Checking Check that the deviation in the bandwidth Deviation is as the values below. ± 3.6 ~ ANT Con WIDE ± 3.60 ~ 4.50 kHz ±4.5kHz NARROW ± 1.80 ~ 2.30 kHz ±...
Page 5
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Checking TX S/N Connect a linear detector via the attenuator to the antenna terminal, and set to the conditions below. 50 Hz 20 kHz De-emphasis OFF Level Meter (P/P)/2 Apply a 1 kHz signal from the low frequency oscillator to the mic terminal, and transmit, then adjust the low frequency...
Page 6
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Checking RX Check that the signal generator level when Sensitivity the RX frequency bandwidth becomes 12 dB SINAD, is the value below. RX Sensitivity Less than -10 dBu Less-10dB ANT Con SP Jack Use the same check method for Narrow...
Page 7
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Adjusting the set the transceiver to the RX frequency Squelch bandwidth’s narrow band center frequency. Set the signal generator to the settings below. ANT Con Modulation Freq. 1kHz WIDE ±...
Page 8
ADJUSTMENT Adjustment Adjustment Condition & Tuning Value Ref. No. CK. Point Checking Set the signal generator output level to AF Output +60 dBu. The transceiver and SG connection is the same as the squelch adjustment above. Adjust the transceiver volume until the distortion meter reads 5%.