Summary of Contents for REVENTON HUMMER SERIES

  • Page 1 Technical documentation INDUSTRIAL AIR CURTAIN HUMMER SERIES MODELS: HUMMER 150C-1P HUMMER 200C-1P HUMMER 150W-1P HUMMER 200W-1P...
  • Page 2: Technical Documentation

    Proceeding due to the following instruction guarantees the correct usage and safety. In case of any doubts please contact Reventon Group sp. z o. o. [Ltd.]. The producer reserves the rights to make changes to the technical documentation without previous notice.
  • Page 3 Parameters HUMMER 150W-1P - 6500 m³/h Parameters HUMMER 150W-1P - 6500 m³/h Parameters HUMMER 150W-1P - 6500 m³/h Supply/return water Supply/return water Supply/return water 90/70 70/50 60/40 temperature[°C] temperature[°C] temperature[°C] Dry bulb air inlet Dry bulb air inlet Dry bulb air inlet temperature [°C] temperature [°C] temperature [°C]...
  • Page 4 HORIZONTAL INSTALLATION 3. ASSEMBLY For horizontal assembly, use the threaded holes on the top of the device, to hang 3.1. GENERAL PRINCIPLE the curtain e. g. on mounting pins. In order to dampen possible vibrations of the structure, it is recommended to use anti-vibration mounts. The elements The curtain can be mounted both horizontally (e.
  • Page 5 3.3 OUTLET GRILLE - it is recommended to check the leak tightness of the hydraulic system before The HUMMER series curtain has a movable outlet grille that allows adjustment plugging the electric supply of the airflow angle. The maximum deviation of the stream axis from the perpendicular direction to the grid plane should not exceed the maximum 4.2 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM...
  • Page 6 We offer the following controls: Programmable controller HMI CURTAIN is used to adjust the operation of curtains HUMMER series, which are equipped with three-speed fans. It is an advanced driver with many functions i. e. operation in thermostatic mode (heating or cooling) or in accordance with door sensor, valve operation control, selection of the fan speed.
  • Page 7 7. CONNECTION SCHEMES LEGEND: 1. Power 2. Main switch, overcurrent circuit breaker* 3. HUMMER curtain fan 4. Programmable controller HMI CURTAIN 5. Valve with actuator HC 3/4''' 6. Door switch 7. Relay module RM-16A *Main switch and overcurrent circuit breaker are not included in the device...
  • Page 9 8. TERMS OF WARRANTY I. Producer Reventon Group Sp. z o.o. [Ltd.] grants the buyer a 24-month warranty period for the following devices: - industrial air curtain HUMMER 150C-1P - industrial air curtain HUMMER 200C-1P - industrial air curtain HUMMER 150W-1P - industrial air curtain HUMMER 200W-1P II.
  • Page 10 Warranty card...