WATER HEATED AIR CURTAIN
MODELS:
AERIS 100WN-1P
AERIS 150WN-1P
AERIS 200WN-1P

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERIS 100WN-1P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for REVENTON AERIS 100WN-1P

  • Page 1 Technical documentation WATER HEATED AIR CURTAIN MODELS: AERIS 100WN-1P AERIS 150WN-1P AERIS 200WN-1P...
  • Page 2: Technical Documentation

    Proceeding due to the following instruction guarantees the correct usage and safety. In case of any doubts please contact Reventon Group sp. z o. o. [Ltd.]. The supplier reserves the rights to make changes to the technical documentation without previous notice.
  • Page 3: Technical Data

    2.2.TECHNICAL DATA TECHNICAL DATA AERIS 100WN-1P AERIS 150WN-1P AERIS 200WN-1P Product code AC100WN1P AC150WN1P AC200WN1P 17.0 26.1 37.1 III BIEG 24.1 34.0 Power of the device [kW]* 15.8 II BIEG 14.2 21.9 31.4 I BIEG III BIEG 1500 2250 3250 Maximum airflow [m³/h]...
  • Page 4 AIR FLOW Model: = 8m/s = 7m/s STAGE = 9m/s STAGE STAGE REVENTON V=2250 m3/h V=2000 m3/h V=1750 m3/h AERIS ∆P ∆P ∆P 150WN-1P °C °C °C °C °C °C 26.1 1150 22.7 36.5 24.1 1062 19.6 38.5 21.9 16.6 40.5...
  • Page 5: Installation

    -install mounting plate on the wall 3. INSTALLATION 3.1. GENERAL PRINCIPLES The following figures show minimum distances between the air curtain and the building partition: -install the main body. Set the main body onto the upper end of the mounting plate and clamp it as shown 2.3 m b) ceiling mounting (using mounting studs)
  • Page 6: Precautions And Warnings

    - it is recommended to use a filter on the curtain’s hydraulic power supply 6. CONTROLS Usage of automatic control dedicated to the air water heaters of Reventon - it is recommended to use the following valves: Group gives great possibilities of adjusting the efficiency of the curtain vent valve in the highest place on the hydraulic installation ź...
  • Page 7: Connection Schemes

    7. CONNECTION SCHEMES LEGEND: 1. Power 2. Main switch, overcurrent circuit breaker* 3. Water heated air curtain AERIS WN-1P 4. 3-stage speed controllers with thermostat HC3S A-work in continuous mode B-operation in thermostatic mode 5. Two-way valve with actuator HC ¾ " 6.
  • Page 8 VIII. Any changes in the Warranty Terms, improper use of the product (careless handling, exposure to liquids, moisture, corrosion), as well as traces - water heated air curtain AERIS 100WN-1P of selfrepairing (non by the Reventon Group) or alterations cause, the warranty - water heated air curtain AERIS 150WN-1P is not valid.