Paytel P6 Series Mechanical Integration Manual page 15

Table of Contents

Advertisement

Copyright © 2018 PAYTER
BV. All rights reserved. No
part of this document may be
reproduced in any form by
print, photo print, microfilm,
electronic copy or any other
means without written
permission by Payter BV.
3XX
This error range covers transaction related errors
1. Perform network trouble shooting
2. Try reloading the terminal configuration files
301
Transaction host error, this fault code indicates a specific
issue that occurred while the Host was processing a
transaction.
This error range covers errors related to the contactless
4XX
interface. Perform a test with another contactless card or
token to validate that the card is not the cause of the
problem. If
XX
Terminal internal error.
1XX
If the result code is not specifically listed, but falls in one of
5XX
these categories then the terminal has an internal error,
6XX
contact your local supplier for assistance.
7XX
Table 19 – Result code description
Display message
"Wait for network"
"Recover network"
"NO SAM"
"Invalid Arguments"
"Initializing"
Table 20 – Display message description
Description
No active network connection
detected.
Network connection Lost
No SAM module detected during
startup.
No valid configuration is present
If the terminal remains in this state it
is not receiving commands from the
vending machine.
P6X Mechanical Integration Guide
Possible Solution
Perform LAN or mobile internet
trouble shooting
Perform LAN or mobile internet
trouble shooting
Check the settings for
MDB/PVP/CCI.
Page 15 / 21

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Paytel P6 Series

This manual is also suitable for:

P68P66P66s

Table of Contents