Advertisement

P6X Mechanical Integration Guide
Payter B.V.
Rozenlaan 115
3051 LP Rotterdam
The Netherlands
P6X Mechanical Integration Guide
Document version
: 1.0
Document status
: Release
Date
: 30-01-2017
Document ID
: PTR-40-10-ML-C-0004-01
NOTICE
This manual contains intellectual property, including but not limited, to trade
secrets and know-how, operating procedure and production procedures that
belong solely to Payter B.V.
Disclosure and/or use and/or reproduction of any part of this document strictly
forbidden, except under a written license from Payter B.V.
All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other
Copyright © 2010 Payter..
means without written permission by Payter BV.

Advertisement

Table of Contents
loading

Summary of Contents for Paytel P6 Series

  • Page 1 P6X Mechanical Integration Guide Document version : 1.0 Document status : Release Date : 30-01-2017 Document ID : PTR-40-10-ML-C-0004-01 NOTICE This manual contains intellectual property, including but not limited, to trade secrets and know-how, operating procedure and production procedures that belong solely to Payter B.V.
  • Page 2: Revision History

    P6X Mechanical Integration Guide Revision History Change Author Initial Release Payter Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other means without written Page 2 / 21 permission by Payter BV.
  • Page 3 P6X Mechanical Integration Guide Abbreviation list Abbreviation Description Third Generation (mobile communication system) Coffee Credit Interface Direct Current DHCP Dynamic Host Control Protocol Domain Name Server EDGE Enhanced Data for GSM (Global System for Mobile communication) Evolution Europay Mastercard Visa European Vending Association GPRS General Packet Radio Service (mobile communication system)
  • Page 4: Table Of Contents

    P6X Mechanical Integration Guide Table of Contents Revision History ....................1 Dimensions & Mounting................. 5 Device opening ......................... 5 Mounting options ......................6 Dimensions P68 The Arc ....................8 Dimensions P66 The Plane ....................9 Dimensions The Angle Casing ..................10 Installation P66 Split .......................
  • Page 5: Dimensions & Mounting

    P6X Mechanical Integration Guide Dimensions & Mounting The majority of the Vending Machines have a provision for installing Payment Terminals. The dimensions of the P6X Terminal series are based upon the EVA (European Vending Association) standard. Device opening Mounting a P6X terminal series requires a device opening that complies to the EVA EPS – Standard door model measurements (Fig.
  • Page 6: Mounting Options

    P6X Mechanical Integration Guide Mounting options Installation option 1: In case no weld studs are provided as indicated in Fig 19, Payter can provide a mounting frame which can be secured through 4mm mounting holes, located at the indicated weld stud positions. EVA Front Mounting Set Section View Fig.
  • Page 7 P6X Mechanical Integration Guide Installation option 2: In case the vending machine comes with pre-installed studs the mounting frame is not required. An additional cover plate can be ordered for a clean finish of the front. The cover plate is secured with double sided adhesive for a strong connection. Fig.
  • Page 8: Dimensions P68 The Arc

    P6X Mechanical Integration Guide Dimensions P68 The Arc The thickness of the Vending Machine or cabinet should not exceed 10 mm to ensure a proper magnetic stripe card swipe. Fig. 22 – P68 The Arc Measurements Copyright © 2018 PAYTER BV.
  • Page 9: Dimensions P66 The Plane

    P6X Mechanical Integration Guide Dimensions P66 The Plane Fig. 23 – P66 The Plane Measurements Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other means without written Page 9 / 21 permission by Payter BV.
  • Page 10: Dimensions The Angle Casing

    P6X Mechanical Integration Guide Dimensions The Angle Casing All dimensions are in mm. Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other means without written Page 10 / 21 permission by Payter BV.
  • Page 11: Installation P66 Split

    P6X Mechanical Integration Guide Installation P66 Split P66S is identical to the P66 terminal with the exception that the card reader and the communication is split into two parts. The card reader can be mounted on top of any machine, while the communication unit is located inside the machine.
  • Page 12: Dimensions P66S Split Unit

    P6X Mechanical Integration Guide Dimensions P66S Split Unit Front Unit Communication Unit Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other means without written Page 12 / 21 permission by Payter BV.
  • Page 13: Technical Specifications

    P6X Mechanical Integration Guide Technical Specifications Contactless Interface EMVCo. L1 v2.5 Certified Integrated MSR 3 Track ISO14443 Type A & B (T=CL) Contact Card Interface EMV L1 v4.3 Certified Mifare Classic protocol SAM Card Interface 3 SAM Slots, IS07816 T=O and Desfire protocol Human Interface 4 Blue LEDs...
  • Page 14: Troubleshooting

    P6X Mechanical Integration Guide Troubleshooting Result Codes Result Codes Description 00 - 199 Terminal Internal errors 500 - 799 “ 200 - 299 Network infrastructure related errors 300 - 399 Transaction related errors 400 - 499 Contactless interface related issues Table 18 - Result code categories.
  • Page 15 P6X Mechanical Integration Guide This error range covers transaction related errors 1. Perform network trouble shooting 2. Try reloading the terminal configuration files Transaction host error, this fault code indicates a specific issue that occurred while the Host was processing a transaction.
  • Page 16: Lan Troubleshooting

    P6X Mechanical Integration Guide LAN troubleshooting When a network connection cannot be established, perform the following checks: Solution No Network Check the LAN cable is connected properly, on the terminal connector the connection orange and the green LEDs should indicate link-up and activity. If not double check if the cable is connected properly in the terminal and the patch outlet.
  • Page 17 P6X Mechanical Integration Guide Use the Diagnostics features of the Vend Settings Tool to see if and how the terminal is connected to the network. Fig. 24 - LAN status information Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm,...
  • Page 18: Mobile Internet Troubleshooting

    P6X Mechanical Integration Guide Mobile Internet troubleshooting Solution Verify whether the data SIM card is placed. ‘….’ Icon Blinking If the data SIM card has a PIN code, set it up in the terminal, or remove the (No GSM signal) PIN.
  • Page 19: Warnings

    P6X Mechanical Integration Guide Warnings AC Adapter • Use only power adapters that come with the terminal. • Do not use the adapter if the cord becomes damaged. • Do not disassemble the AC adapter. Only qualified technicians may service the adapter.
  • Page 20: Installation Guide

    P6X Mechanical Integration Guide Installation Guide Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other means without written Page 20 / 21 permission by Payter BV.
  • Page 21 P6X Mechanical Integration Guide Copyright © 2018 PAYTER BV. All rights reserved. No part of this document may be reproduced in any form by print, photo print, microfilm, electronic copy or any other means without written Page 21 / 21 permission by Payter BV.

This manual is also suitable for:

P68P66P66s

Table of Contents