No Signal
No Signal Delay
No Signal Power
Off
Control Button
Lock
Remote Controller
Lock
Menu lock
Auto Source
Switch
Power Up Settings
Initial startup
Sets the behavior preference of the Display, when no signal is detected from the currently
set input source. Image Search and Input Search options are available.
If Image Search is selected the Display checks the connected USB device for available
files to play. If no playable files are available or there is no USB device connected to
the Display, the No Signal image will be displayed. If there isn't any No Signal Image
available, No Signal OSD will be displayed on the screen. The setting of the USB Auto
Play option in the Settings>System>More menu is not important, in Image Search
mode it will function anyway.
If Input Search is selected the Display will search all available input sources consecutively
to find signal. If no signal is detected from other available sources, No Signal OSD will
be displayed and the Display will turn itself off after a period of 30 seconds.
How to install No Signal Image
Install the file you want to use onto the root directory of any USB storage device and name
it as "NoSignalImage.png". Connect the USB storage device to the Display. Highlight
USB Operations option in the Settings>Signage>USB menu and press ENTER.
Sets a delay value to the 'No Signal' preferences when the Display is in No Signal state.
After the set delay time is expired 'No Signal' preferences will be applied. If the No Signal
option is set as Input Search, this option will not be available.
When enabled the Display will turn itself off after a period of 5 minutes, if no signal is
received from the selected source.
This feature will only work if all of the following circumstances occur:
- No Signal option is set as Image Search.
- USB device is not connected to the Display / USB device is connected but there are
no playable files installed on the USB device.
If the No Signal option is set as Input Search, this option will not be available.
Set as Off to prohibit the use of the buttons on the Display.
Set as On to inhibit the use of the remote. Remote control will function in Stand-By
mode independently from the setting of this option.
To turn this option off and be able to use the remote again, press MENU/M-1-9-7-3
buttons on the remote consecutively. Signage menu will appear. Enter the Controls
menu and set this option as Off.
Note: The Standby button is valid even if set to On.
You can block the usage of the menu button on the remote by setting this item as All
menus. When you press the menu button, you will be asked to enter the PIN that
you have defined in the First Time Installation. Set as Off to disable this function.
If this option is enabled the Display will switch to the currently active HDMI source
automatically when a device is connected to the Display through the HDMI1 or
HDMI2 input terminal. Set as Enabled to enable this feature.
When the HDMI source is removed the Display will switch to other active HDMI
source. If there isn't any other device connected to the Display and the HDMI Wake
UP option for the related HDMI source is enabled the Display will switch into the
standby mode.
There is also a 3-second restriction for the successive connected HDMI sources.
This means, second HDMI device must be plugged in 3 seconds after the first HDMI
device is plugged in.
Note: This feature applies for HDMI1 and HDMI2 input terminals only. Refer to the
General View section to see the HDMI inputs.
Configures the power up mode preference. Last State, Always On and Standby