Download Print this page

Benchmark Green Storage WB Series Installation & Maintenance Instructions Manual page 10

Cylinders 90/120/150/180/210/250/300 litre

Advertisement

Green Storage WB Range
Installation & Maintenance Instructions
TECHNICAL PERFORMANCE AND SPECIFICATION DATA - FICHE
Nominal
Product Codes
Capacity
Worcester Bosch / OMC
(Litre)
Indirect unvented hot water cylinders & Pre-Plumb variants
90
7-733-601-298 / GSSC90ERP
120
7-733-601-299 / GSSC120ERP
150
7-733-601-300 / GSSC150ERP
180
7-733-601-301 / GSSC180ERP
210
7-733-601-302 / GSSC210ERP
250
7-733-601-303 / GSSC250ERP
300
7-733-601-304 / GSSC300ERP
Solar twin coil unvented hot water cylinders & Pre-Plumb variants
180
7-733-601-306 / GSTC180ERP
210
7-733-601-307 / GSTC210ERP
250
7-733-601-308 / GSTC250ERP
300
7-733-601-309 / GSTC300ERP
PARTS LIST
Installation and maintenance instructions
Spare part no: 8-716-121-839
Download www.worcester-bosch.co.uk
Inlet control set – with balanced Cold
3 bar PRV 6 bar expansion relief
Spare part no: 8-716-121-840
Temperature & pressure relief valve
/
" NPT x 15mm
1
2
Spare part No: 8-716-121-841
10
Energy
Standing
Rating
Loss (W)
C
49
C
54
C
59
C
67
C
75
C
84
C
93
C
67
C
75
C
84
C
93
Total
Weight
Height
Empty (kg)
761
30
933
35
1120
35
1308
45
1496
50
1746
55
2059
60
1308
60
1496
65
1746
70
2059
75
Anti splash tundish
15 x 22 mm
Spare part no: 8-716-121-842
External expansion vessel - DHW
Units 250L & under - 19 litre vessel
Spare part no: 8-716-121-843
300L units - 24 litre vessel
Spare part no: 8-716-121-844
Actual
Weight
Capacity
Full (kg)
(Litre)
117.9
87.9
155.1
120.1
185.4
150.4
225.6
180.6
260.6
210.6
305.9
250.9
360.3
300.3
228
178
259.6
204.6
307
247
360.6
295.6

Advertisement

loading