Fume Exhaust - Electrolux 7GRGDGC0P Manual

Table of Contents

Advertisement

3.1. JOINING APPLIANCES
• (Fig.1A) Undo the 4 fixing screws and remove the control
panels of the appliances.
• (Fig.1B) Remove the fixing screw nearest the control panel,
from each side to be joined.
• (Fig.1D) Bring the appliances together and level them by
turning the feet until the tops match.
• (Fig.1C) Turn one of the two plates inside the appliances 180º.
• (Fig.1E) From inside the control panel of the same ap-
pliance, join them at the front side, screwing one M5x40
Hex Head screw (supplied) on the opposite insert.
• (Fig.1F) From the rear of the appliances, insert the cou-
pling plate (provided) in the side slots on the back panels.
Secure the plate with two flathead M5 screws provided.
3.2. FLOOR FIXING
To avoid accidental tipping of built-in half-module appliances instal-
led separately, fix them to the floor carefully following the instructions
enclosed with the corresponding accessory (F206136).
3.3. INSTALLATION ON BRIDGE, CANTILEVER FRAME
OR CEMENT PLINTH
Carefully follow the instructions enclosed with the corresponding
accessory. Follow the instructions supplied with the optional
product chosen.
3.4. SEALING GAPS BETWEEN APPLIANCES
Follow the instructions supplied with the optional sealing paste pack.

4. FUME EXHAUST

For Australia, ventilation must be in accordance with
australian building codes and kitchen exhaust hoods must
comply with AS/NZS1668.1 and AS 1668.2
4.1. TYPE "A1" APPLIANCES
Position type "A1" appliances under an extraction hood to
ensure removal of fumes and steam produced by cooking.
• SUB CLAUSE 4.1 is not relevant for australian standard
18