CAUTION
!
If the setup SD card is not removed, the measurement data will begin to be saved after
approx. 5 minutes. The setup data are still kept. Please change the SD card if the
measurement data are not meant to be saved onto this card.
Correct and safe functioning is only guaranteed with genuine SD cards of the
manufacturer (see Operating Instructions "Accessories", Section 8).
5.4.5
Setup via USB stick
Save the unit settings on the PC onto a USB stick using the PC software supplied. This setup
file can then be imported into the unit.
NOTICE
In order to be able to use this function, the unit must already be created in the PC database
or has to be created beforehand. In addition, there has to be a free USB socket on the PC.
CAUTION
!
Never remove the USB stick from the unit without previously launching the function "Extras
–> USB stick –> Remove safely" as data could be lost otherwise.
Procedure for setup using a USB stick:
1.
Copy the setup to the USB stick:
– Insert the USB stick into the USB A socket on the unit front or rear.
– In the Extras menu, select "USB stick –> Save setup".
– In the Extras menu, select "USB stick –> Remove safely".
– Remove the USB stick from the unit and insert it into the USB socket on the PC.
2.
Start the PC software and create a new unit in the PC database:
– Select "Unit –> Display/change unit setup/Add new unit"
– Select "Unit –> Add new unit"
– Enter unit identifier. Select "Parameter file from a data source (e.g. diskette, ATA
Flash, CF, SD)" to transmit the unit setup. Confirm with "Next". Select the corresponding
unit parameter file (*.rpd) from the USB stick. Confirm with "Next". A summary of the
information on the new unit is displayed. When you click "OK", the new unit is created
in the PC database.
3.
Adjust setup in the PC program and save in the associated database:
- Adjust the unit settings.
– Select "Finished –> Save setup in unit database". The new setup parameters are saved
in the PC database. Transfer the new SETUP file to the USB stick in your PC: select
"Finished –> Create setup data carrier (diskette/ATA flash/CF/SD)" and select the
suitable drive.
– Remove the USB stick from the PC and insert it into the USB A socket on the unit.
4.
Read in new setup directly at the unit:
– In the Extras menu, select "USB stick –> Load setup". To remove the USB stick, select
"USB stick –> Safe removal" in the Extras menu. Repeat these steps to configure
additional units with this setup.