3.25 Libraries
3.25.1 How to install
In order to read/write MICRO-EHV+ series PLC's specific information, the following libraries are available. Add
necessary CmpHIESLib_MV by choosing "Add library" as shown below.
CmpHIESLib_MV is Hitachi-IES's special library including;
2 Phase counters
Single counters
Interrupts
Pulse Trans outputs
PWM outputs
If these libraries are not found in the library list as above, install library by choosing [Tools]-[Install library...].
3 – 85
Chapter 3
Programming