l i nd ab | we s im pli fy co ns t r uc t io n
Installation instruction
4.4.2 Example 1: Wiring scheme with
Regula Connect multi
Please visit
www.lindQST.com
"Wiring scheme
configurator" for your set-up.
Regula Presence SL
Power
Regula Convert
Regula Sensor Philips
Actuator on/off
24V heating
g
NB: Wire colours
differ from standard
Actuator on/off
24V cooling
NB: Wire colours
differ from standard
4.4.3 Example 2: Wiring scheme with Regula
Connect basic
Actuator on/off
24V heating
g
NB: Wire colours
differ from standard
Actuator on/off
24V cooling
NB: Wire colours
differ from standard
18
and check out the
4 wire RJ11 6P4C, Straight through
When a 4-pipe water connection
is ordered (plus feature),
an actuator can be connected on the
heating circuit as well.
(Geyed out).
Condensation sensor
1 Whi
7
2 Red
8
Bro
4
Blu
5
NB: Wire colours differ from standard
When a 4-pipe water connection
is ordered (Plus feature),
an actuator can be connected on the
heating circuit as well.
(Geyed out).
Condensation sensor
1 Whi
7
2 Red
8
Bro
4
Blu
5
NB: Wire colours differ from standard
Lindab reserves the right to make changes without prior notice
Regula Combi
›
OFF
STANDBY
COOL
SERVICE
HEAT
21
22
40
32
31
41
ends must
be insulated
NB: Wire colours
differ from standard
To other Regula Connect Multi
To other Regula Connect Multi
Bro
1
2
Blu
Regula Combi
›
OFF
STANDBY
COOL
SERVICE
HEAT
NB: Wire colours
differ from standard
To other Regula Connect Basic
To other Regula Connect Basic
Bro
1
Blu
2
2021-03-02
Plexus
REGULA CONNECT
T568B
White/Orange
1
Orange
2
White/Green
3
Blue
4
White/Blue
5
Green
6
{
White/Brown
7
Brown
8
Presence
adapter
Blu
Bro
Blu
Bro
23
Whi
24
Grn
11
Bro
10
Yel
4
3
2
1
4
3
2
G0-
1
Blk
Blk
Red
G+
Red
LINDAB
REGULA CONNECT
Basic
Blu
Bro
Blu
Bro
23
Whi
24
Grn
11
Bro
10
Yel
4
3
2
1
4
3
2
G0-
1
Blk
Blk
Red
G+
Red
LINDAB
Multi
Rc LINK
N = Neutral
L = Load
S = Signal
Rc LINK
RC in/out
CO2 in - S
CO2 in - S
CO2 out - N
CO2 out - L
Presence in - S
Presence in - S
Presence out - N
Presence out - L
Damper out - S
Damper out - N
Damper out - L
Heating out - S
Heating out - N
Heating out - L
Cooling out - S
Cooling out - N
Cooling out - L
Heating in - S
Cooling in - S
Supply out - N
Supply out - L
Heating link - S
Cooling link - S
Supply link - N
Supply link - L
Heating link - S
Cooling link - S
Supply link - N
Supply link - L
Supply in - N
Supply in 24V - L
N = Neutral
L = Load
S = Signal
Heating out - S
Heating out - N
Heating out - L
Cooling out - S
Cooling out - N
Cooling out - L
Heating in - S
Cooling in - S
Supply out - N
Supply out - L
Heating link_S
Cooling link_S
Supply link - N
Supply link - L
Heating link_S
Cooling link_S
Supply link - N
Supply link - L
Supply in - N
Supply in - 24V - L