Download Print this page

Rabbit RCM4300 Getting Started page 3

Advertisement

Figure 3. Connect Programming Cable and Power Supply
Connect the other end of the programming cable to an available USB port on your PC or workstation.
Your PC should recognize the new USB hardware, and the LEDs in the shrink-wrapped area of the USB
programming cable will flash — if you get an error message, you will have to install USB drivers. Drivers
for Windows XP are available in the Dynamic C Drivers\Rabbit USB Programming Cable\
WinXP_2K folder — double-click DPInst.exe to install the USB drivers. Drivers for other operating
systems are available online at www.ftdichip.com/Drivers/VCP.htm.
Step 5 — Connect Power
Once all the other connections have been made, you can connect power to the Prototyping Board.
First, prepare the AC adapter for the country where it will be used by selecting the plug. The RCM4300
Development Kit presently includes Canada/Japan/U.S., Australia/N.Z., U.K., and European style plugs.
Snap in the top of the plug assembly into the slot at the top of the AC adapter as shown in Figure 3, then
press down on the spring-loaded clip below the plug assembly to allow the plug assembly to click into
place. Release the clip to secure the plug assembly in the AC adapter.
Connect the AC adapter to 3-pin header J1 on the Prototyping Board as shown in Figure 3. The connector
may be attached either way as long as it is not offset to one side—the center pin of J1 is always connected
to the positive terminal, and either edge pin is ground.
Plug in the AC adapter. The PWR LED on the Prototyping Board next to the power connector at J1 should
light up. The RCM4300 and the Prototyping Board are now ready to be used.
NOTE: A RESET button is provided on the Prototyping Board next to the battery holder to allow
a hardware reset without disconnecting power.
1
Insert tab into slot
Assemble
AC Adapter
2
Snap plug into place
3-pin
power connector
Programming
Cable
Colored
edge
C5
C21
R36
U3
LINK
R33
R31
C15
DS2
R32
R41
SPEED
RX43
RX97
RX49
R42
DS4
UX3
AC Adapter
J1
U1
C1
C2
BT1
UX49
UX47
J2
L1
C6
+5 V
GND
GND
/RST_OUT
/IORD
+3.3 V
RCM1
/IOWR
/RST_IN
VBAT
PA0
EXT
PA1
PA2
PA3
PA4
R17
R16
JP16
R3
R1
JP6
PA5
PA6
R2
C18
JP5
R4
JP12
R19
PA7
PB0
JP4
JP3
R22
JP14
PB1
PB2
JP8
R23
C16
JP7
R70
R71
PB3
PB4
JP18
C10
JP9
JP1
JP10
PB5
PB6
PB7
PC0
R25
C11
PC1
PC2
JP4
Q1
JP5
PC3
PC4
JP6
JP12
PC5
PC6
JP7
JP13
PC7
PE0
JP8
R29
JP14
JP9
PE1
PE2
JP10
PE3
PE4
R20
R19
JP11
PE5
PE6
R10
R9
PD0
PE7
LN0
R30
C15 C16 R28 R27 R26
PD1
PD2
LN1
LN2
PD4
PD3
LN4
LN3
PD6
PD5
LN6
LN5
RX59
RX75
RX55
RX57
PD7
C91
CVT
RX73
LN7
C93
VREF
AGND
CX25
DS2
JP25
J3
S2
C92
C90
RESET
1
S1
RESET
UX4
RX81
RX83
RX11
UX30
UX10
RX67
UX12
UX14
CX27
CX23 RX77
RX79
DS3
R21
UX16
R22
R23
R24
GND
1
1
S3
GND
GND

Advertisement

loading