Selecting The Operating Mode; Setting The Clock - Honeywell PLS530A Owner's Manual

Programmable wall switch
Hide thumbs Also See for PLS530A:
Table of Contents

Advertisement

Available languages

Available languages

PLS530A/PLS531A
NEW 3-WAY INSTALLATION
120 VAC
The jumper wire is not required in this installation. A
single-pole switch can be used as the other switch in a 3-
way installation.
3. POWER-ON
1. Pry the switch door open
from the bottom using a
small screwdriver.
2. Ensure the ON/OFF
selector is set to ON.
3. Reset the switch using a
paper clip. 0:00 and MO
will flash.
If the display is blank:
• Ensure the ON/OFF selector is properly engaged in the
ON position. Push it to the right using a small
screwdriver.
• If the programmable switch controls a lamp equipped
with a built-in On/Off switch, ensure the lamp switch is
set to On.
• Ensure the light bulb is not burned out and is tightly
screwed in its socket.
EXISTING 3-WAY INSTALLATION
If either switch does not work properly, rewire the jumper
between the "common" screw and the other screw.
WARNING: BEFORE REPLACING THE LIGHT BULB,
PLACE THE ON/OFF SELECTOR IN THE OFF POSITION.
FAILURE TO DO SO MIGHT DAMAGE THE SWITCH.

4. SETTING THE CLOCK

NOTE: The switch displays the time in 24-hour format by
default or following a reset.
1. To change to 12-hour format (or vice versa), proceed
as follows:
a. Press one of the control buttons to ensure the
MAN or AUTO indicator is displayed.
b. Press the MIN and HOUR buttons simultane-
ously and briefly (0:00 display = 24-hour, 12:00
display = 12-hour).
2. Set the time using the HOUR and MIN buttons. If you
have selected the 12-hour format, ensure that PM
appears on the screen when an afternoon time is
displayed.
3. Set the day by using the DAY button.
4. Press one of the control buttons or close the switch
door to return to normal operation.
69-2502EFS—05
See NOTE
Reset
Control (4)
On/Off selector
5. SELECTING THE
OPERATING MODE
The programmable switch has 2 operating modes: manual
(MAN) and automatic (AUTO). To switch mode, press the
switch door for 3 seconds.
Manual Mode
The programmable switch operates as a
regular switch. Briefly press the switch
door to turn the lights On or Off. The
mode (MAN) and state (ON or OFF) are
displayed.
Automatic Mode
The programmable switch follows the pro-
grammed schedule. The mode (AUTO),
state (ON or OFF) and current program
number are displayed.
To temporarily override the programmed schedule, press
the switch door. The new state (ON or OFF) will flash to
show that this state is temporary. The override remains in
effect until you press the switch door again or until the
beginning of the next program.
6. PROGRAMMING
You can set up to 7 programs. To set a program, you need
to enter its start time (ON) and its end time (OFF).
1. Pry the switch door open using a small screwdriver.
2. Press the PGM button to display a
program and its On or Off time. For
example, when you first press PGM,
program number 1 (P1) and its On
time (ON) will appear. - : - - will
appear instead of the time if the program is not set
(inactive).
3. Press the DAY button to select the
day to which you want to apply the
program.
NOTE: If you want to apply the program
to every day of the week, press DAY until all the
days are displayed. (This still counts as 1 pro-
gram, not 7)
4. Press the HOUR and MIN buttons to set the ON time
(time when you want the lights to turn on). If you
have selected the 12-hour format, ensure that PM
appears on the screen when an afternoon time is
displayed.
5. After you have programmed the ON time, press the
PGM button to display the OFF time (time when you
want the lights to turn off).
6. Repeat steps 3 through 5 to program
the OFF time. If the program ON time
is set for every day of the week, the
program OFF time will automatically
be set for every day.
7. To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
8. Press one of the control buttons or close the switch
door to return to normal operation.