C
T
ECHNICAL

Related Standards

The 3Com Baseline Switch 2226-PWR Plus has been
designed to the following standards:
Functional
MAC Address
Safety
EMC Emissions
Immunity

Environmental

Operating Temperature 0–45 °C (32–113 °F)
Humidity
Standard
I
NFORMATION
ISO 8802-3, IEEE 802.3 (Ethernet),
IEEE 802.3u (Fast Ethernet), IEEE
802.3ab and IEEE 802.3z (Gigabit
Ethernet), IEEE 802.3x (Flow Con-
trol), IEEE 802.1D 1998 (Bridging)
4096
UL 60950-1 & CAS 60950-1
(CSA/CUS), IEC 60950-1(CE), EN
60950-1 (T
V/GS)
Ü
EN 55022 Class A, FCC Part 15
Subpart B Class A, ICES-003 Class
A, VCCI Class A
EN 55024
10–95% (non-condensing)
EN 60068 (IEC 68)—various parts

Physical

Width
Length
Height
Weight
Mounting

Electrical

Power Inlet
AC Line Frequency
Input Voltage
Current Rating
Maximum Power Con-
sumption
Maximum Power Dissi-
pation
PoE Maximum Output
Power per Port
The Switch can also provide power to any PoE-com-
pliant device that is connected to any of its 24 Ether-
net ports (based on the IEEE 802.3af Power over
Ethernet specifications).
440 mm (17.3 in.)
235 mm (9.2 in.)
43.6 mm (1.75 in.) or 1U.
3.2 kg (7.6 lb)
Free-standing, or 19 in.
rack-mounted using the supplied
mounting kit
IEC 320
50/60 Hz
100–240 VAC
3 ampere (maximum)
196 watts
668.95 BTU/hr
15.4 watts