ctrlX HMI DE0015, DE0021 Multi-Touch
Displays (Housing Devices)
WARNING
The E-STOP button can be used as operating element in an E-STOP circuit.
The E-STOP circuit has to be designed by the machine manufacturer.
Only qualified staff may connect the E-STOP button and check it afterwards.
It has to be connected acc. to the connection scheme
connection scheme" on page
The max. load current is 500 mA.

9.8.1 Overview

Name at the
Connection
housing
type
CN1
Keypad con-
nection
CN2
Keypad con-
nection
Tab. 9-3: Keypad interfaces

9.8.2 Keypad connection scheme

S1
NOT-HALT
Fig. 9-5: Keypad connection diagram
Death or lethal injury due to incorrect handling
of the E-STOP button
17.
Connector type (integrated)
Phönix pin contact strip,
6-pin, MCV 1,5/6-G-3,5
Phönix pin contact strip,
10-pin, MCV 1,5/10-G-3,5
CN2
S2
S3
chapter 9.8.2 "Keypad
Mating connector or cable (from
outside)
Phönix socket strip,
6-pin, FK-MCP 1,5/6-ST-3,5
Phönix socket strip,
10-pin, FK-MCP 1,5/10-ST-3,5
CN1
S4