Download Print this page
F&F PCS-516UNI Manual

F&F PCS-516UNI Manual

Timing relays, 10-function
Hide thumbs Also See for PCS-516UNI:

Advertisement

Quick Links

Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: fif@fif.com.pl
TIMING RELAYS
10-function
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase. Contact your
dealer or directly with us. More informa-
tion how to make a compliant can be
found on the website:
www.fif.com.pl/reklamacje
5
9 0 8 3 1 2
Do not dispose of this device in the trash along with other waste! According
to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the
occasion of the purchase of new equipment (in accordance with the principle
of old-for-new, regardless of brand). Electro thrown in the trash or abandoned
in nature, pose a threat to the environment and human health.
PURPOSE
Lagged-pulse time relay PCS-516 is devised to support the power
supply of the controlled receiver for a specified period of time
after decay of the control voltage, e.g. in bathroom ventilation
systems in which the upkeep of the fan operation (activated
along with the lighting) is required for a specified period of time
after turning off the accompanying lighting.
ATTENTION!
- With the power supply ON, the system does not respond to
time range setting modifications.
- The newly set time range is active after the power supply has
been turned OFF an ON.
- With the power supply on, it is possible to regulate the preset
time freely within the selected time range.
- 1 -
B
U
t
DELAY DEACTIVATION
Until the relay is activated, the contact remains in the 11-10
position. After the power voltage is supplied (green LED is
shining), the contact is shifted to position 11-12 and the count-
down of the preset value „t" is commenced (red LED is shining).
The working sequence of the relay may be repeated after turning
the power voltage off and on.
C
U
t
t
DELAY ACTIVATION - CYCLIC
The DA operational mode is triggered in equal interruption/work
cycles according to preset time values.
D
U
t
t
t
DELAY DEACTIVATION - CYCLIC
The DD operational mode is triggered in equal interruption/work
cycles according to preset time values.
- 3 -
F&F Filipowski sp. j.
PCS-516
UNI
5 9 1 4 2 9
t
t
t
t
t
U
F
E
D
FUNC
G
C
H
B
I
knob choose optopn
A
K
6
7
5
8
4
9
3
10
2
11
1
12
10s 1m
1s
10m
0,1s
2h
knob choose option
T?
OFF
1d
ON
2d
PCS-516
WORK TIME SETTINGS
By time range switch T- set one of choosen range and by time knob
T× set value on the scale from 1 to 12. Product of this values egual
work time „t" (e.g. t= 1m×7= 7 min).
SETTINGS OF WORK MODE
By choose option knob FUNC set one of functions (e.g. function
A- delay activation).
WORK FUNCTIONS
A
U
t
DELAY ACTIVATION
After the power voltage is supplied (green LED is shining), the
contact remains in position 11-10 and the timing of the preset
value „t" is commenced. After the preset time „t" has been
counted down, the contact is shifted to position 11-12 (red LED is
shining). The working sequence of the relay may be repeated after
turning the power supply OFF and ON.
- 2 -
E
U
0,5 s
t
Generate impulse 0,5 s after set time „t".
F
U
t
Generation of a single impulse of „t" time by the START signal
eading edge. During preset time countdown, the system does not
respond to START impulses.
G
U
t
Generation of a single impulse of „t" time by the START signal
trailing edge. During preset time countdown, the system does not
respond to START impulses.
- 4 -
work mode
knob
set time
range time
t
t

Advertisement

loading

Summary of Contents for F&F PCS-516UNI

  • Page 1 F&F Filipowski sp. j. Konstantynowska 79/81 95-200 Pabianice phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND http://www.fif.com.pl e-mail: fif@fif.com.pl FUNC PCS-516 TIMING RELAYS knob choose optopn 10-function work mode T× knob WARRANTY. The F&F products are 10s 1m set time covered by a warranty of the 24 months 0,1s...
  • Page 2 Turning off the relay for a specified period of time along the Delay in deactivation with support function enabled. The leading leading edge of the START signal. During the preset time count- edge of the START signal results in relay activation, where as the down the system does not respond to START signals.

This manual is also suitable for:

5908312591429