Specifications - Honeywell FF-SRS5988 Instructions For Use Manual

Dual channel emergency stop module
Table of Contents

Advertisement

SPECIFICATIONS

Input
Nominal voltage
(Dual voltage device)
Nominal power consumption
Nominal frequency
Start time
Nominal voltage at S11
at S21
Input current between
S11/S12 and S21/S23
Minimum voltage at S12/A4
and at S22/A4
Cable resistance between
S11/S12 and S21/S23
Output
Contact complement
Response time
Contact type
Switching Capability
Current Range (min. to max.)
Voltage Range (min. to
Switching Capability per
(EN 60 947-5-1)
Typical Electrical Life
Expectancy 3A
Typical Power Factor (cos ϕ)
Operating frequency
Output contact fuse rating
Mechanical life
General
Temperature range
Sealing
Housing material
Vibration resistance
Wire/connector connection
Wire/connector attachment
Mounting
Weight
NOTE 1:
Install arc suppression device across load to avoid module contact
arcing and ensure specified relay life expectancy.
NOTE 2 Total operations = operations at power factor 1 multiplied by the
limitation factor.
If the power factor is 0.5 at 230 Vac, 3A (1,000,000
operations), the limitation factor is 0.70. 1,000,000 x 0.70 = 700,000 total
operations.
2
120 Vac (-20%, +10%) / 24Vdc (-10%, +20%)
230 Vac (-20%, +10%) / 24Vdc (-10%, +20%)
DC: 3 W; AC: 6 VA
50 to 60 Hz
Manual START function: 30ms
Automatic START function: 1 s
24 Vdc (provided by control module)
0 V
110 mAdc
21 Vdc when activated
68 Ω (max.)
6 NO, 1 NC contacts
Opening of inputs (S11/S12; S21/S23):
30 ms;
Opening in supply circuit: 50 ms
Safety relay, positive-guided
Power factor = 1 with resistive load
1 mA to 10A (see Caution)
0.1 to 250 Vac/dc
max.)
NO contact: 5 A/ 230 V
NC contact: 2A / 230 V
AC15
Power factor = 1 at 230 Vac/dc (see fig. 1,
note 1)
5A
1,000,000 operations
10A
500,000 operations
220,000 operations
Limitation Factor (see fig. 2, note 2)
0.3
0.45
0.5
0.70
0.7
0.85
1.0
1.00
600 switching cycles/hour
Time delay 6 A (max.)
Thirty million switching operations
-15°C to + 55°C (5°F to 131°F) at 90%
humidity (max.)
Housing IP 40; Terminals IP 20
Thermoplastic
Amplitude 0.35 mm; Frequency 10 to 55 Hz
2
1 x 4 mm
solid (max.) [12 AWG] or 2 x 1.5
2
mm
(max.) [16 AWG] stranded wire with
sleeve DIN 46288
Removable terminals block with M3.5
screws; wire contacts are enclosed to prevent
electrical shock
Quick install rail mounting EN 50022-35;
width: 35 mm (1.38 in.)
840 g (1.85 lb.)
FIG 1. CONTACT LIFE FOR
100% RESISTIVE LOAD (typical)
(note 1)
power factor = 1 (cos ϕ)
FIG 2. LIMITATION FACTOR
FOR INDUCTIVE LOADS (note 2)
power factor < 1 (cos ϕ)
CONTACT DAMAGE
To ensure the 1 mA capability
during the lifetime of the contact,
NEVER exceed 300 mA and 60V.
Failure to comply with these
instructions will result in loss of
low current switching capability.