INSTALLATION INSTRUCTIONS

INDOOR UNIT INSTALLATION
1.
Fit the Installation Plate
1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete or
the like, drill eight (8) 5mm diameter holes
in the wall. Insert wall plug for appropriate
mounting screws.
3. Fit the installation plate on the wall with eight
(8) type "A" screws.
Note:
Fit the Installation Plate and drill holes in the wall according to the wall structure
and corresponding mounting points on the installation plate.
(Dimensions are in "mm" unless otherwise stated)
Indoor unit outline
120mm or more
to wall
Left refrigerant
pipe hole
65
2. Drill a hole in the wall
1. Determine hole positions according to
the diagram detailed in Fig.5. Drill
one (1) hole ( 80mm) slanting slightly
to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate or the like.
Installation Instruction
5
150mm or more to ceiling
70
( 16000Btu/h model)
A:780
Fig.5
Correct orientation
of Installation Plate
Installation plate
70
( 16000Btu/h model)
, 920
Indoor
Fig.4
120mm or more
to wall
Right refrigerant
pipe hole
65
Wall
Outdoor
Fig.6