Preface Preface The aquastream ULTIMATE pump is built for longevity and to match the highest quality standards. It has been particularly designed for PC water cooling systems. Each pump is meticulously submitted to a test run; therefore you might find some moist residues within the pump.
Should you be using a plug-on reservoir with the pump (e. g. aquainlet series), re- move the silver suction grille and mount the tank directly onto the water inlet port of the aquastream ULTIMATE pump. In this case no connecting adapter is to be installed into the inlet port.
USB and aquabus interface can be used at the same time, how- ever not all control options of the aquastream ULTIMATE are available using the aquabus interface.
Take special care to disconnect the 4pin or 8pin ATX12V power supply connector from the motherboard as well. Connect the pow- er connector of the aquastream ULTIMATE to an available SATA power plug of the power supply unit.
Configuration using USB connection Configuration using USB connection The aquastream ULTIMATE can be connected to a PC via USB interface and can then be configured using the aquasuite software. Comprehensive visualization and logging options are also available in the aquasuite software. However, an USB connection is not required for operation.
This includes data from connected USB devices as well as hardware data supplied by the Aqua Computer background service. Displayed data may be filtered using the text box next to the magnifier icon, a chart shows the develop- ment over a maximum of ten minutes.
AQUASTREAM ULTIMATE In contrast, the “Data log” may be used to selectively and permanently store data from all connected Aqua Computer devices and hardware data supplied by the background service. Logged data can then be analyzed by creating charts or be exported to files.
Pump configuration Pump configuration aquasuite: Select “Pump” from the device list below the “aquastream ULTIMATE” entry. In the upper area, current pump data is displayed as plain text as well as in a diagram. Select the desired mode of operation below the diagram.
Fan configuration Fan configuration aquasuite: Select “Fan” from the device list below the “aquastream ULTIMATE” entry. In the upper area, current fan data is displayed as plain text as well as in a diagram. Select the desired mode of operation below the diagram.
The start boost feature can be used to reliably power up a fan or pump connected to the output. If activated, the aquastream ULTIMATE controller will set the fan out- put to the 100 % power for a short duration before switching to normal operation whenever the output power changes from exactly 0 % setting to a higher value.
Software temperature sensors Software temperature sensors can be used to transfer temperature sensor readings to the aquastream ULTIMATE from the computer by USB connection or from an aquaero 5/6 by aquabus connection. Two procedures are implemented: 1. Sensor data is transmitted from an aquaero 5/6 connected to the aquas- tream ULTIMATE via aquabus.
Display configuration and information pages Display configuration and information pages Display configuration and information pages aquasuite: Select “Display” from the device list below the “aquastream ULTIMATE” entry. Device menu: Select “Display” from the menu list and confirm by pressing the mid- dle key.
If only one device is connected via aquabus, this step may be skipped. Address 17 and 18 are available. Please note that aquastream ULTIMATE and aquastream XT as well as D5 NEXT share resource assignments in the aquabus device handling of the aquaero.
Click the entry “aquasuite web” to publish data on the internet or import data from the internet. The server for this service is operated by Aqua Computer and provid- ed for use with the aquasuite, without warranty for for error free operation or per- manent availability.
Data import Data import To import a data set from the Aqua Computer server, the “access key” of the data set is required. The access key can be found in the aquasuite on the computer providing the data in the “Data access” section.
18.4. 18.4. Service administration Service administration Service administration Service administration The service (background service) configures special USB settings for all connected Aqua Computer devices and should therefore always be active. 18.5. 18.5. 18.5. 18.5. License manager License manager License manager License manager All aquasuite versions starting with annual version 2017 require a valid license.
7264509 Suction grille 41086 7263609 All spare parts can be obtained from Aqua Computer. Eheim spare parts may also be available from local aquarium supply stores. 20. Technical details and care instructions Technical details and care instructions Technical details and care instructions Technical details and care instructions 20.1.
24/7. To get in direct contact with our customer support team, we offer several options: email: support@aqua-computer.de Address: Aqua Computer GmbH & Co. KG Gelliehäuser Str. 1 37130 Gleichen Germany Tel: +49 (0) 5508 9749290 (9-16 h CET, German and English language) - 28 - Aqua Computer GmbH &...
Need help?