Fry Warmer
Essayer d'installer ce four risque de causer des blessures graves ou la mort, ou
d'endommager l'équipement. Veillez à ce que ce soit un fournisseur de service autorisé
de BKI qui installe le four.

Instructions for Shipping Damage

You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for
damage when they arrive. If there is damage noted to shipping crates or cartons, or, if a shortage is found, note
this on the bill of lading (all copies) before signing.
If damage is detected when the equipment is uncrated, immediately call the delivering truck line and follow up the
call with a written report indicating concealed damage to your equipment. Ask for an immediate inspection of your
concealed damage item. Crating material MUST be retained to show the inspector from the truck line.

Electrical Information and Grounding

Il pourrait y avoir électrocution, défaillance du matériel ou dégâts matériels si l'installation
électrique est faite par un électricien non agréé. Veillez à ce qu'un électricien agréé
effectue l'installation conformément aux codes national et local.
Le FW-15DTO dispose de 2 cordons d'alimentation. Assurez-vous que chaque cordon
ATTENTION
est connecté à un circuit d'alimentation séparé. Débranchez toujours les deux cordons
d'alimentation avant de réparer, déplacer ou tester l'unité.
BKI Fry Warmers are wired for use in accordance with all applicable local, state, and federal codes. For specific
electrical requirements and connections refer to the wiring diagram attached to the unit or provided in the Service
Manual.

Installation Instructions

FW-12 & FW-12T (Side Breather)
Countertop Adapter (FW-12 only)
1. Obtain a suitable countertop location for the unit that will provide a clearance of 4" from the side louvers.
2. Position the adapter (WN31206400) on the countertop.
3. Using a 1/8" drill bit, drill holes in the countertop used to secure the adapter to the countertop.
4. Using a 2" hole saw, drill a hole in the countertop (directly under the hole in the adapter) used for the
power cord to pass through.
5. Secure adapter to countertop with # 8 sheet metal screws.
6. Seal adapter to the countertop to conform to NSF Standard 4, Item 4.28. (Dow Corning RTV #732 Multi
purpose Sealant.)
If a side or back panel is removed on the chute, the other two sides must be sealed with
NSF approved silicone. Seal all inside seams greater than 1/32".
This unit must be sealed to the counter after it is installed to conform to NSF Standard 4,
Item 4.28. (Dow Corning RTV #732 Multi purpose Sealant.)