Advertisement

Quick Links

Confidentiality Notice ............................................................................................................... 3
Safety and Care Information .................................................................................................... 3
Product Overview ...................................................................................................................... 4
Models ................................................................................................................................................ 5
System Requirements and Limitations ........................................................................................... 5
Features and Functions .................................................................................................................... 6
Operation ................................................................................................................................... 6
Placing a General Telephone Call ................................................................................................... 6
Receiving a Call ................................................................................................................................. 6
Monitoring and Reporting ............................................................................................................... 6
Installation ................................................................................................................................ 8
General Information ......................................................................................................................... 8
Station Placement .............................................................................................................................. 8
Model 116-02-0418-00W (Flush mounting) .................................................................................... 9
Model 116-02-0418-01W (Surface mounting) ............................................................................... 13
Setup ........................................................................................................................................ 15
Field Wire Installation .................................................................................................................... 15
Power ........................................................................................................................................................... 15
Network ....................................................................................................................................................... 16
I/O ................................................................................................................................................................ 17
Recommended Cabling ................................................................................................................................ 18
VoIP Telephone Input Contacts .................................................................................................... 18
VoIP Telephone Output Contacts ................................................................................................. 18
Status Indication ............................................................................................................................. 18
ON................................................................................................................................................................ 18
Heartbeat ...................................................................................................................................................... 18
LINK ............................................................................................................................................................ 18
Programming .......................................................................................................................... 19
Maintenance ............................................................................................................................ 20
General Information ....................................................................................................................... 20
Service .............................................................................................................................................. 20
Troubleshooting .............................................................................................................................. 21
GAI-Tronics, a division of Hubbell Ltd, Brunel Drive Burton upon Trent DE13 0BZ, UK
V
.
ISIT WWW
HUBBELL
G A I - T R O N I C S ®
A D I V I S I O N O F H U B B E L L L T D
T
A B L E O F
+44 (0) 1283 500500 ◼ Fax: +44 (0) 1283 500400
.
/
-
/
COM
GAI
TRONICS
EN FOR PRODUCT LITERATURE AND MANUALS
Pub. 502-20-0160-002 iss1
®
C
O N T E N T S
®
.................................................................... 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAI-Tronics Clean Phone 1193 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hubbell GAI-Tronics Clean Phone 1193

  • Page 1: Table Of Contents

    Maintenance ..........................20 General Information ........................20 Service .............................. 20 Troubleshooting ..........................21 GAI-Tronics, a division of Hubbell Ltd, Brunel Drive Burton upon Trent DE13 0BZ, UK +44 (0) 1283 500500 ◼ Fax: +44 (0) 1283 500400 ISIT WWW HUBBELL...
  • Page 2 IP C LEAN HONE ELEPHONES Specifications .......................... 22 GAI-Tronics, a division of Hubbell Ltd, Brunel Drive Burton upon Trent DE13 0BZ, UK +44 (0) 1283 500500 ◼ Fax: +44 (0) 1283 500400 ISIT WWW HUBBELL TRONICS EN FOR PRODUCT LITERATURE AND MANUALS...
  • Page 3: Voip Clean Phone ® Telephones

    This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party. Safety and Care Information The safety instructions for these products are contained in a separate document, no 502-20-0171-001, which is included as a paper copy with every individual telephone and is available online from: https://www.hubbell.com/gai-tronics/en/iom-user-guides...
  • Page 4: Product Overview

    . 502-20-0160-002 iss 1 4 of 24 ® IP C LEAN HONE ELEPHONES Product Overview The GAI-Tronics Model 116-02-0418-00W Flush-Mount and Model 116-02-0418-01W Wall-Mount ® VoIP Clean Phone Telephones are designed for the exacting requirements of clean rooms. They are constructed of stainless steel and have a completely smooth polyester front panel that will not trap particulate matter.
  • Page 5: Models

    . 502-20-0160-002 iss 1 5 of 24 ® IP C LEAN HONE ELEPHONES Models ® The following VoIP Clean Phone Telephones are detailed in this manual: Table 1. Model Chart Model Description 116-02-0418-01W Surface-Mount VoIP Telephone including a stainless steel front panel with polyester overlay, three autodial buttons, hookswitch push button, off-hook indicator, keypad, and stainless steel surface-mount enclosure.
  • Page 6: Features And Functions

    . 502-20-0160-002 iss 1 6 of 24 ® IP C LEAN HONE ELEPHONES Features and Functions Telephone’s voice-over-internet protocol (VoIP) include the following features: ® The Clean Phone • SIP compatible (RFC3261) • Automatic call divert (memory list) • Real-time alarm reporting via SNMP or TMA software •...
  • Page 7 . 502-20-0160-002 iss 1 7 of 24 ® IP C LEAN HONE ELEPHONES • Keypad error (if applicable) • Key hook (off hook status, if applicable) • Register fail • Audio Path Test (speaker/microphone test)
  • Page 8: Installation

    . 502-20-0160-002 iss 1 8 of 24 ® IP C LEAN HONE ELEPHONES Installation General Information CAUTION Do not install this equipment in areas other than those indicated on the approval standards listing in the “Specifications” section of this manual. Such installation may cause a safety hazard and consequent injury or property damage.
  • Page 9: Model 116-02-0418-00W (Flush Mounting)

    . 502-20-0160-002 iss 1 9 of 24 ® IP C LEAN HONE ELEPHONES Model 116-02-0418-00W (Flush mounting) The mounting and wiring instructions are as follows: 1. Remove the front panel from the back bracket. 2. Refer to Figure 5 on page 11 for cut-out details. Use the cut-out dimensions as a guide to mark the wall, and make the required cuts.
  • Page 10 . 502-20-0160-002 iss 1 10 of 24 ® IP C LEAN HONE ELEPHONES Figure 4. Inside Front Panel...
  • Page 11 . 502-20-0160-002 iss 1 11 of 24 ® IP C LEAN HONE ELEPHONES Figure 5. Wall Cut-out Dimensions for Model 112-02-0418-00W...
  • Page 12 . 502-20-0160-002 iss 1 12 of 24 ® IP C LEAN HONE ELEPHONES Figure 6. Mounting bracket for Model 116-02-0418-00W Figure 7. Front Panel...
  • Page 13: Model 116-02-0418-01W (Surface Mounting)

    . 502-20-0160-002 iss 1 13 of 24 ® IP C LEAN HONE ELEPHONES Model 116-02-0418-01W (Surface mounting) The mounting and wiring instructions are as follows: 1. Remove the front panel from the back box. 2. If using Power-over-Ethernet, without any optional inputs or outputs, place the bushing around the Ethernet cable so that it is located approximately 120mm from the end of the cable.
  • Page 14 . 502-20-0160-002 iss 1 14 of 24 ® IP C LEAN HONE ELEPHONES Figure 8. Mounting the Model 116-02-0418-01W...
  • Page 15: Setup

    . 502-20-0160-002 iss 1 15 of 24 ® IP C LEAN HONE ELEPHONES Setup Field Wire Installation After all the field wires are pulled through the rear enclosure, install all connections as indicated below. Refer to Figure 9 for wiring details. Refer to Table 5 on page 18 for the recommended conductor sizes.
  • Page 16: Network

    . 502-20-0160-002 iss 1 16 of 24 ® IP C LEAN HONE ELEPHONES Network Connect a Cat5 or Cat5e cable with an RJ45 connector between the Local Area Network (LAN) and the VoIP PCBA. Figure 9. VoIP Telephone PCB Assembly...
  • Page 17: I/O

    . 502-20-0160-002 iss 1 17 of 24 ® IP C LEAN HONE ELEPHONES Inputs Four auxiliary inputs have been provided for customer use. Terminations for these inputs are provided on terminal block P12. Table 3. Auxiliary Inputs – P12 Label Function Input 4 Common...
  • Page 18: Recommended Cabling

    Each VoIP Clean Phone section of this manual for the input ratings. The function of each input is configurable. Please refer to the VoIP Telephone Configuration Guide (available from www.hubbell.com/gai-tronics/en/voip-support) for programming instructions for these inputs. VoIP Telephone Output Contacts ®...
  • Page 19: Programming

    SIP protocol) between the desired locations before attempting to configure the GAI-Tronics VoIP Telephones. Full programming and configuration details are contained in the Configuration guide, available from www.hubbell.com/gai-tronics/en/voip-support The factory defaults will generally be sufficient in most cases, but the following steps must be taken as a minimum: •...
  • Page 20: Maintenance

    By choosing GAI-Tronics as your aftercare provider you are ensured of manufacturer expertise and ISO 9001-certified quality control standards throughout the life of the product. We can also supply a full range of accessories including mounting posts, beacons and high-volume sounders. Contact GAI-Tronics for details. www.hubbell.com/gai-tronics/en...
  • Page 21: Troubleshooting

    . 502-20-0160-002 iss 1 21 of 24 ® IP C LEAN HONE ELEPHONES Troubleshooting Table 6. Troubleshooting Chart Problem Possible Solution If the volume is low, increase the volume level in the telephone’s Low volume programming configuration. If the volume is high, decrease the volume level in the telephone’s High volume programming configuration.
  • Page 22 . 502-20-0160-002 iss 1 22 of 24 ® IP C LEAN HONE ELEPHONES Specifications Power Network power............Power-over-Ethernet, 802.3af compliant (via RJ45) Local power requirements ..................24–48 V dc, 6 watts Network ..............10/100 BaseT Ethernet RJ45, Cat5 or Cat5e UTP Static IP Provisioning or DHCP Call control signaling ...............
  • Page 23 . 502-20-0160-002 iss 1 23 of 24 ® IP C LEAN HONE ELEPHONES ® The Clean Phone graphic overlay is NOT resistant to the following: Concentrated mineral acids High pressure steam at over 100º C Methylene chloride Concentrated caustic solution Benzyl alcohol UV exposure Dimethylformamide...
  • Page 24 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) Directive CE Declaration A copy of the current CE Declaration of Conformity is available from our website. https://www.hubbell.com/gai-tronics/en/product-certificates-uk Recycling The symbol shown here and on the product means that the product is...

This manual is also suitable for:

116-02-0418-00w116-02-0418-01w

Table of Contents