Solcon RVS-BX Series Instruction Manual

Solcon RVS-BX Series Instruction Manual

Compact soft starter

Advertisement

Quick Links

R
V
S
-
R
V
S
-
C
o
m
p
a
c
t
S
o
C
o
m
p
a
c
t
S
o
8
-
8
5
A
,
2
2
0
-
8
-
8
5
A
,
2
2
0
-
I
n
s
t
r
u
c
t
i
o
n
I
n
s
t
r
u
c
t
i
o
n
Ver. 1.4.2002
B
X
B
X
f
t
S
t
a
r
t
e
r
f
t
S
t
a
r
t
e
r
6
0
0
V
6
0
0
V
M
a
n
u
a
l
M
a
n
u
a
l

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RVS-BX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Solcon RVS-BX Series

  • Page 1 Ver. 1.4.2002...
  • Page 2 Table of Contents Page Subject Starter Selection Installation Notes Wiring Starter Settings Start-up Procedure Dimensions Technical Specification Safety • Read this manual carefully before operating the equipment and follow its instructions. • Installation, operation and maintenance should be in strict accordance with this manual, national codes and good practice.
  • Page 3 Starter Selection The RVS-BX is a Basic Analogue soft starter which The starter should be selected in accordance with the incorporates six thyristors to start a three phase squirrel following criteria: cage induction motor. By supplying a slowly increasing voltage, it provides soft start and smooth 1.
  • Page 4 Installation Notes 1. Prior to Installation 6. Overload and Short Circuit Protection Check that Motor's Full Load Ampere (FLA) is lower The RVS-BX should be protected against a short than or equal to starters Full Load Current (FLC) and circuit by Thyristor Protection fuses. that Mains voltage is as indicated on the front panel.
  • Page 5 Wiring Stop / Start......... Terminals 1 - 2 Block and Connection Diagram By voltage free contact (Dry contact) Close: Start command. Open : Stop command. Warning RVS -BX Do not apply voltage to terminals 1 - 2. Reduced Voltage Starter End of Acceleration (E.O.A) ..
  • Page 6 Starter Settings and Startup Procedure Front Panel Layout Startup Procedure ° ° ° 1. Set front panel potentiometers as follows: Initial Voltage ° ° • Initial voltage to 30%. • Ramp Up Time to 5 sec. 2. Install a clamp-type ammeter on one of the lines. Ramp 3.
  • Page 7 Dimensions & Weights S=6m m S=2.5mm 2 S=1.5m m R V S -BX R educed Voltage S tarter RVS - BX Reduced Voltage Starter 181.5 =1.5mm S=16mm S=2.5mm 2 L L L 1 2 3 RVS - BX Reduced Voltage Starter U V W RVS - BX Reduced Voltage Starter...
  • Page 8 Vibration resistance 2 gn Conforming to EN 60947-4-2 Output relay End of Acceleration Contact N.O. Rated operating current 5 A, 250 V - Size B1 8 A, 250 V – Size B2-B4 N:\eli\Eli's 95_bup\Solcon-CD for Distributors 05-03-2002\Instruction Manuals\RVS-BX Instruction Manual1.doc...