Download Print this page

Connecting The Power - KEN BROWN KBH-5000W Manual

Heavy-duty fan-forced ceiling-mount heater

Advertisement

MULTIPLE VERTICAL ANGLES

CONNECTING THE POWER

HEATER
RATING&VOLTAGE
5000W@240V
Circuit diagram
Warning: This appliance must be grounded!
Warning: The appliance must be connected to a current protection circuit or
Amp
device before being connected to power supply!
1. Remove the screw from the front of the unit to connect the power to the heater.
2. Attach the cable connectors to the unit (See Figure 8) and slide the 10-gauge wire
through the cable connector.
3. Connect the wire to the power block located in the base of the heater - See Figure
4. Turn on the power at the main service.
Figure 6
HEATER
FUSE
AMPS
SIZE
20.9
Figure 7
MIN.WIRE SIZE
75°C COPPER
30
#10
30
9.