LOCATING THE HEATER
Install heater out of traffic areas, maintaining clearances stated in figure 1. The direction of
airflow should not be restricted by columns or machinery and the airflow should wipe
exposed walls rather than blowing directly on them. When more than one heater is used in
an area, the heaters should be installed so that the air discharge of each heater supports the
air flow of the others, to provide best circulation of warm air as indicated in figure 2.
14in.
1
12
in.
2
Note:Min. clearance to ceiling
when not using mounting brackets
5
is 1
in.
8
FRONT VIEW
MINIMUM
MINIMUM
DISTANCE
DISTANCE
TO WALL
TO WALL
7
in.
3
13in.
8
1 3 4in
.
MAXIMUM MOUNTING HEIGHT:
Vertical air delivery unit = 11 ft.
Horizontal air delivery unit =8 ft.
SIDE VIEW
Figure 1
Figure 2
10
3
in.
5
4
in.
4
1
in.
1 2
2
1 2in. ., 3 4in.
DISTANCE
TO FLOOR
At least 8 ft.
24 in.
MINIMUM
DISTANCE
FROM
DISCHARGE
TO ANY
OBJECT