OPTICAL COMMUNICATION
13
When the setting of data bank loading / saving, copy setting, or copy action
However, in case using data bank loading / saving, use FX-502
loading / saving, or copy setting cannot be carried out.
• Copy lock setting is set to copy lock ON "
• Digital display is blinking
bank loading / saving)
When communication protocol of a
sub amplifier is set to communication
emission halt "
" the setting
of data bank loading / saving, or copy
setting cannot be carried out to sub
Make sure to mount closely like follows
since interference prevention function is
conducted by optical communication.
sensor controllers, etc.) are connected together in cascade, install those prod-
Communication direction
A
B
D
C
FX-MB1 (optional) on the communication window of each
corresponding product.
Within each group, identical models should be connected in a lump.
In case conducting copy setting of this device and other FX-500 series togeth-
er, functions which are incorporated in this device will be copied but functions
which are not incorporated in this device will not be copied.
14
INTERFERENCE PREVENTION FUNCTION
ting frequencies from an interference prevention function by optical communication.
For Interference prevention function setting procedure, refer to <PRO5> in
"PRO MODE OPERATION MANUAL."
as shown in table below.
Response time
Interference
H-SP
prevention function setting
0
• Possible number of interference prevention is 4.
8th to OFF since interference prevention works from 1st to 4th, from 5th to
8th and 9th to 12th.
Communication direction
Interference prevention
possible range
Put a protection seal between
Or set communication protocol
setting in 4th to OFF.
For communication protocol setting procedure, refer to <PRO4> in "PRO
MODE OPERATION MANUAL."
FX-505 -C2
."
"
." (Only data-
Communication direction
Main
Model No.
FX-301
A
FX-301B G H
LS-401
FX-301
B
FX-305
FX-301 -C1
C
LS-403
DPS series
D
FX-500 series
FAST
STD
2
4
8
8
Interference
Interference prevention
prevention
possible range
possible
Put a protection seal between
range
Or set communication protocol
setting in 8th to OFF.
ERROR INDICATION
15
In case of errors, attempt the following measures.
Error
indication
EEPROM is broken or reached the end of its
working life.
EEPROM writing error
Load of the sensing output 1 is short-circuited
Load of the sensing output 2 is short-circuited
mounted in cascade.
Communication error between the upper com-
16
SPECIFICATIONS
Type
Model No.
Supply voltage
Power consumption
(Note 1)
Sensing output
(Sensing output 1 / 2)
Output operation
-
Short-circuit protection
Response time
External input
Protection
Ambient temperature
Ambient humidity
Material
Weight (Main body only)
Accessory
Notes: 1) 50mA max. if 5 or more series connection types are connected together.
2) In case of using the quick-connection cable (cable length 5m) (optional).
3) Cables are not accessories. Be sure to use cables in table below.
<Series connection type>
-
Cable length 1m
Main cable
CN-74-C1
17
CAUTIONS
This product has been developed / produced for industrial use only.
Take care that if a voltage exceeding the rated range is applied, or if an AC
-
power supply is directly connected, the product may get burnt or be damaged.
Take care that short-circuit of the load or wrong wiring may burn or damage
the product.
Do not run the wires together with high-voltage lines or power lines, or put
them in the same raceway. This can cause malfunction due to induction.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that the frame
In case noise generating equipment (switching regulator, inverter motor, etc.)
12
of the equipment to an actual ground.
-
extraneous noise since the sensitivity of that is higher than the other modes.
Make sure to check the environment before use.
Be sure to using the quick connection cable (optional) as cable. When you ex-
tend the cable, be sure to use cables which have 0.3mm
cross-section area. Extension up to total 100m is possible. However, in order
to reduce noise, make the wiring as short as possible.
Make sure that stress by forcible bend or pulling is not applied to the sensor
This product is suitable for indoor use only.
Avoid dust, dirt, and steam.
Take care that the product does not come in contact with oil, grease, organic
solvents such as thinner, etc., strong acid or alkaline.
plosive gasses.
Never disassemble or modify the product.
This product adopts EEPROM. Settings cannot be done 100 thousand times
or more because of the EEPROM's lifetime.
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
PRINTED IN JAPAN
Description
Turn OFF the power and check the load.
Verify that there is no loose or clearance between
Verify that there is no loose or clearance between
Series connection type
NPN output
FX-502
12 to 24V DC
% Ripple P-P10% or less
Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
Eco mode: 680mW or less (current consumption 28mA or less at 24V supply voltage)
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 50mA (Note 1)
• Maximum source current: 50mA (Note 1)
• Applied voltage: 30V DC or less
• Applied voltage: 30V DC or less
(Between sensing output and 0V)
• Residual voltage: 2V or less (Note 2)
• Residual voltage: 2V or less (Note 2)
[At 50mA (Note 1) sink current]
Switchable either Light-ON or Dark-ON
Incorporated
• Signal condition
• Signal condition
High: +8V to +V DC or Open
High: +4V to +V DC (at 3mA sink current)
Low: 0 to +1.2V DC (at 0.5mA source current)
Low: 0 to +0.6V DC or Open
IP40 (IEC)
-10 to +55°C (If 4 to 7 units are mounted in cascade: -10 to +50°C or if 8 to 16 units are
mounted in cascade: -10 to +45°C) (No dew condensation or icing allowed)
Storage: -20 to +70°C
35 to 85% RH, Storage: 35 to 85% RH
Enclosure: Polycarbonate, Key: Polyacetal, Protective cover: Polycarbonate
Approx. 15g
FX-MB1
Cable
Cable length 2m
Sub cable
Main cable
Sub cable
CN-72-C1
CN-74-C2
CN-72-C2
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Remedy
PNP output
FX-502P
(Between sensing output and +V)
[At 50mA (Note 1) source current]
Cable length 5m
Main cable
Sub cable
CN-74-C5
CN-72-C5
2
or more of conductor
-

Advertisement

loading

This manual is also suitable for: