Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and
optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
INTENDED PRODUCTS FOR CE MARKING
1
This product complies with the following standards / regulations.
<EU Directive>
EMC Directive 2004/108/EC
<Standards in US / Canada>
ANSI/UL 60947-5-2, CAN/CSA C22.2 No.14
<Regulations in Korea>
S1-G-1-2009, S2-W-5-2009
Caution about UL recognition
In case requiring conformity of UL listing mark or C-UL listing mark, USe class
2 power supply unit.
Contact for CE
<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
2
PART DESCRIPTION
UP key
Teaching
Threshold value
¿QH DGMXVWPHQW
Select setting items
<Reference>
Sensing output
Digital display
operation indicator
(Green / Red)
(Orange)
MODE indicator: L / D (Yellow)
MODE indicator: CUST (Yellow)
Pressing down SET key + MODE key for 3 sec : Set key lock or release key lock
3
MOUNTING
How to connect
1. Fit the rear part of the mounting sec-
WLRQ RI WKH DPSOL¿HU RQ D ',1 UDLO
2. Press down the rear part of the
mounting section of the unit on the
DIN rail and fit the front part of the
mounting section to the DIN rail.
How to remove
1. Push the controller forward.
2. /LIW XS WKH IURQW SDUW RI WKH DPSOL¿HU
to remove it.
+RZ WR FRQQHFW WKH ¿EHU FDEOH
%H VXUH WR ¿W WKH DWWDFKPHQW WR WKH ¿EHUV ¿UVW EHIRUH LQVHUWLQJ WKH ¿EHUV WR WKH
DPSOL¿HU )RU GHWDLOV UHIHU WR WKH LQVWUXFWLRQ PDQXDO HQFORVHG ZLWK WKH ¿EHUV
1. Snap the fiber lock lever down till it
stops completely.
2. ,QVHUW WKH ¿EHU FDEOHV VORZO\ LQWR WKH
inlets until they stops. (Note)
3. Return the fiber lock lever to the
original position till it stops.
1RWH :LWK WKH FRD[LDO UHÀHFWLYH W\SH ¿EHU VXFK DV FD-G4 or FD-FM2 LQVHUW WKH VLQJOH FRUH ¿EHU FDEOH LQWR WKH
EHDPHPLWWLQJ LQOHW ³3´ DQG WKH PXOWLFRUH ¿EHU FDEOH LQWR WKH EHDPUHFHLYLQJ LQOHW
If they are inserted in reverse, the sensing performance will deteriorate.
INSTRUCTION MANUAL
MJE-FX501C No.0035-73V
SET key
DOWN key
Teaching
Teaching
C o n f i r m s e t t i n g
7KUHVKROG YDOXH ¿QH
contents
DGMXVWPHQW
Select setting items
MODE key
Select Modes
Cancel during setting
MODE indicator: PRO (Yellow)
2. Press down
1. Fit
35mm width DIN rail
1. Push forward
2. Lift up
3. Return
1. Snap
Fiber lock lever
Fiber for emitter
2. Insert
Fiber for
receiver
4
INSTALL MORE AMPLIFIER OF SERIES CONNECTION TYPE
Make sure that the power supply is OFF while adding or removing the series
connection type.
In case 2 or more the series connection types are connected in cascade,
make sure to mount them on a DIN rail.
,Q FDVH LQVWDOOLQJ DGGLWLRQDO DPSOL¿HU RI VHULHV FRQQHFWLRQ W\SH WKH PD[LPXP
WKH VHULHV FRQQHFWLRQ W\SHV XVLQJ VXE FDEOHV FDQ EH DGGHG WR DQ DPSOL¿HU
using a main connection cable.
When connecting 2 or more the series connection types in cascade, use the
sub cable (optional) for the second series connection type onwards.
)RU PRXQWLQJ DQG UHPRYLQJ WKH DPSOL¿HU UHIHU WR ³
How to cascade
1. 0RXQW WKH DPSOL¿HUV RQH E\ RQH
on the DIN rail.
2. 6OLGH WKH DPSOL¿HUV QH[W WR HDFK
other, and connect the quick-
connection cables.
3. Mount the end plates MS-DIN-E
(optional) at both the ends to hold
the amplifiers between their flat
sides.
4. 7LJKWHQ WKH VFUHZV WR ¿[ WKH HQG
plates.
How to Remove
1. Loosen the screws of the end
plates.
2. Remove the end plates.
3. Slide the amplifiers and remove
them one by one.
I/O CIRCUIT DIAGRAMS
5
<FX-501>
(Brown) +V (Note)
(Black) Sensing output
(Blue) 0V (Note)
<FX-501P>
(Brown) +V (Note)
(Black) Sensing output
(Blue) 0V (Note)
Note: The quick-connection sub cable does not incorporate +V (brown) and 0V (blue). The power is supplied from
the connector of the main cable.
<Terminal arrangement>
1
Terminal No.
1
2
2
3
3
6
OPERATION PROCEDURE
The changed settings are not stored if turning the power OFF while
VHWWLQJ 7KHUHIRUH FRQ¿UP WKH VHWWLQJV E\ SUHVVLQJ WKH 6(7 NH\ EHIRUH
turning the power OFF.
When turning ON the power, RUN mode is displayed and the digital display
shows the threshold value (green) and the incident light intensity (red).
<RUN mode>
Displays threshold value (green) and incident light intensity (red).
7HDFKLQJ WKUHVKROG YDOXH ¿QH DGMXVWPHQW DQG NH\ ORFN IXQFWLRQ
can be set.
For setting method of each function, refer to "
MODE," "
TION," or "
<Sensing output operation mode>
Select either Light-ON or Dark-ON.
For the setting, refer to "
MODE."
The default setting is "
<CUSTOM mode>
An item set in CUSTOM mode (Response time setting, Emission
power setting and Hysteresis setting) is displayed.
For details, refer to "
The default setting is "
<PRO mode>
Advanced setting can be done.
For the setting, refer to "
<RUN mode>
MOUNTING."
Sub cable
(Optional)
Communication
window
End plate
MS-DIN-E (Optional)
Main cable
(Optional)
End plate
MS-DIN-E
(Optional)
Load
+
12 to 24V DC
%
-
+
12 to 24V DC
%
-
Load
Terminal name
+V
Sensing output
0V
TEACHING
THRESHOLD VALUE FINE ADJUSTMENT FUNC-
KEY LOCK FUNCTION."
SENSING OUTPUT OPERATION
" (Light-ON).
CUSTOM MODE."
" (response time setting).
PRO MODE."
Slide
Slide