THIS COPY IS NOT SIGNED SINCE IT IS FILED AND DELIVERED BY MEANS OF THE AUTOMATIC KNOWLEDGE MANAGEMENT SYSTEM (IT CAN BE SIGNED ON REQUEST). THIS DOCUMENT AND THE DATA CONTAINED HERE IN, IS PROPRIETARY PROPERTY AND SHALL NOT BE DUPLICATED, USED OR DISCLOSED – IN WHOLE OR IN PART – FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF OCEM.
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. OCEM - ENERGY TECHNOLOGY warrants to each original Buyer of Products manufactured by the Company that such Products are at the time of delivery to the Buyer, free of material and workmanship defects, provided that no warranty is made with respect to: (a) any Product, which has been repaired or altered in such a way, in Company’s judgement, as to affect...
Document UT-MT-0046_EN Page 3 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE OPERATION ON THE EQUIPMENT - SKILLS Operation on the equipment and access to its internal parts shall be done by experienced personnel, adequately trained and aware of the risks related to electricity and high voltages.
Document UT-MT-0046_EN Page 4 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE REVISIONS Index Date Description Edited by Approved by 04/06/2020 Update option M.Bacciglieri M.Mazzotti LIST OF EFFECTIVE PAGES From page 1 to page 18...
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE GENERAL FP150 elevated light is high intensity, unidirectional steady burning type. These fittings are used for runway edge lighting and provide a candlepower distribution conforming to ICAO Specs - Annex 14 and NATO STANAG 3316 Specs.
Document UT-MT-0046_EN Page 10 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE INSTALLATION CIVIL WORKS Each light is usually installed on a suitable concrete block, into which a pipe elbows is cemented.
Document UT-MT-0046_EN Page 11 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE INSTALLATION For the installation of the light the following steps are suggested: pass together the secondary cable lead with receptacle and a suitable length of grounding wire (grounded inside the pit) through the pipe elbow place the receptacle into the upper threaded section of the pipe elbow, by holding it between the two plastic rings, and pass the grounding wire through the...
4 - Elastic mountings for lamp locking 9 - Grounding bolt 5 - Arrow marked on the lamp support 10 - Hinge between lens plate 6 - Cable leads with plug and body 11 - Levelling and alignment device Figure 5 - FP150 light - Details...
Document UT-MT-0046_EN Page 13 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE NOTE: take as reference the document UT-MT-0770 in case it is available the optical device P/N 332.4401 to level and align the light. 4 MAINTENANCE WARNING BEFORE ANY MAINTENANCE INTERVENTION, MAKE...
7 - Mark and arrow on the top of the half-lenses 1 - Reference on the body for outer lens proper mounting 2 - Reference on the body for inner lens proper mounting Figure 6 - FP150 light - Details...
ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE References on the outer lens for proper mounting on the body Reference/s on the internal lens/es to mount the gasket in fixed posiiton Figure 7 - FP150 light - Details...
Document UT-MT-0046_EN Page 16 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE 4.1.2 Snowplow Operations Snowplow operators should exercise extra care not to strike the light fixtures with snowplow blades. After snow removal operations, inspect all light fixtures to locate and replace, if necessary, any damaged light assemblies.
Document UT-MT-0046_EN Page 17 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE 4.5 REPLACEMENT OF THE CLEAR INNER LENS (ONE PIECE) Remove the three stainless steel clips, which locks the outer lens, by unscrewing the relevant screws;...
Document UT-MT-0046_EN Page 18 of 18 Edition 04/06/2020 Supersedes edition 11/03/2014 ELEVATED RUNWAY EDGE LIGHT FAU INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE Unscrew the four levelling screws making free the assembly body-lens plate-lenses from the column; retain the hardware. Support the above assembly by hand and pull the cable leads with plug and the grounding wire outside the bottom of the body.